Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM65176

A Reliable EMG-Based Robotic Interface for Assistive Mobility with Sensor-Driven Safety Control

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM65176

Volume:

10 |

6 |

Jun 2026

Pages:

1-5

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM65176

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

Yash Vijay Bansod

Yash Vijay Bansod

Department of Computer Science and Engineering

G H Raisoni College of Engineering and Management, Nagpur

Download Author Certificate
RS

Ranjana Shende

Department of Computer Science and Engineering

G H Raisoni College of Engineering and Management, Nagpur

Download Co-Author Certificate

Mentors

RS

Ranjana Shende

Department of Computer Science and Engineering

G H Raisoni College of Engineering and Management, Nagpur

Download Mentor Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Individuals with neuromuscular impairments frequently encounter significant barriers when operating conventional powered mobility devices, most of which assume a baseline level of hand or arm dexterity that may not be present in this population. This paper presents the design, implementation, and experimental evaluation of an embedded robotic interface that translates forearm electromyographic (EMG) activity into differential drive locomotion commands. Two surface EMG channels, acquired through Muscle BioAmp Candy sensors positioned over the left and right forearm flexors, are sampled at 500 Hz and conditioned through a fourth-order Butterworth band-pass filter spanning 74.5–149.5 Hz, implemented as a cascade of biquad sections on an Arduino Uno. A circular-buffer moving-average algorithm extracts the signal envelope, which is compared against a fixed activation threshold to generate directional motor commands through an L298N H-bridge driver. The architecture further embeds three independent hazard-detection mechanisms — ultrasonic ranging for forward obstacle clearance, dual infrared sensing for surface-edge avoidance, and an audible buzzer alert — combined through a conservative interlock that suppresses motor output whenever any safety condition is unmet. Bench evaluation across three subjects confirmed consistent envelope separation between resting (≈14 units) and active (≈65 units) states relative to a threshold of 30, correct execution of all four locomotion states, and zero false negatives across all obstacle and edge trials. The findings support the viability of threshold-driven EMG control, augmented with passive multi-sensor safety logic, as a deployable low-cost assistive mobility solution.

KEYWORDS

surface electromyography assistive robotics Butterworth filter envelope detection obstacle avoidance embedded control differential drive

Cite This Article

Yash Vijay Bansod, Ranjana Shende, Ranjana Shende, "A Reliable EMG-Based Robotic Interface for Assistive Mobility with Sensor-Driven Safety Control," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 6, pp. 1-5, Jun 2026. https://doi.org/10.55041/IJSREM65176

Full Article/Conclusion

This work set out to demonstrate that a differential-drive mobility platform could be reliably governed by forearm EMG signals using threshold logic alone, without resorting to gesture classification, machine learning, or per-user calibration — and the experimental evidence gathered here supports that premise. Dual-channel acquisition through Muscle BioAmp Candy sensors, conditioned via a fourth-order Butterworth band-pass filter and reduced to a stable envelope through circular-buffer averaging, produced a clear and consistent separation between resting (~14) and active (~65) signal states across all three test subjects — a margin wide enough to accommodate the modest inter-subject and inter-session variability observed during testing without any threshold retuning. Equally significant is the performance of the embedded safety architecture. By treating ultrasonic obstacle sensing and infrared edge detection as hard constraints on motor activation rather than advisory inputs, the system achieved zero false negatives across all hazard trials conducted, validating the design decision to prioritize a conservative, fail-to-stop default over continuous operation. This outcome directly addresses the safety-deployment gap identified earlier in the literature, where control sophistication alone has been shown insufficient to guarantee real-world reliability in assistive robotic platforms. Taken together, the results indicate that threshold-based EMG control, when paired with deliberate signal conditioning and a hardware-level safety interlock, offers a practically viable and economically accessible pathway toward assistive mobility — one whose simplicity is not a compromise but rather a design choice suited to the embedded, low-cost context this work specifically targets. Future development directions, including adaptive threshold calibration, proportional speed control derived from envelope amplitude, and expanded lateral hazard sensing, are positioned to extend this platform's applicability toward a broader and more clinically representative user population.

References

  [1]     A. Nanavati, V. Ranganeni, and M. Cakmak, "Physically assistive robots: A systematic review of mobile and manipulator robots that physically assist people with disabilities," Annual Review of Control, Robotics, and Autonomous Systems, vol. 7, 2024. [2]     "EEG and EMG-based human-machine interface for navigation of mobility-related assistive wheelchair (MRA-W)," Heliyon, vol. 10, no. 5, Mar. 2024, Art. no. e27777, DOI: 10.1016/j.heliyon.2024.e27777. [3]     S. Bisi, L. De Luca, B. Shrestha, and Z. Yang, "Development of an EMG-controlled mobile robot," Robotics, vol. 7, no. 3, pp. 36, Jul. 2023. [4]     G. D'Onofrio, L. Fiorini, H. Hoshino et al., "Assistive robots for socialization in elderly people: Results pertaining to the needs of the users," PubMed, 2023. [5]     A. C. Manero, S. L. McLinden, J. Sparkman, and B. Oskarsson, "Evaluating surface EMG control of motorized wheelchairs for amyotrophic lateral sclerosis patients," Journal of NeuroEngineering and Rehabilitation, vol. 19, no. 1, 2022, DOI: 10.1186/s12984-022-01066-8. [6]     F. Grzeskowiak et al., "SWALKIT: A generic augmented walker kit to provide haptic feedback navigation assistance to people with both visual and motor impairments," in 2022 International Conference on Rehabilitation Robotics (ICORR), IEEE, 2022, DOI: 10.1109/ICORR55369.2022.9896406. [7]     R. A. R. C. Gopura, S. Bandara, and M. P. Gunasekara, "Recent trends in EMG-based control methods for assistive robots," in Electrodiagnosis in New Frontiers of Clinical Research, InTech, DOI: 10.5772/56174. [8]     World Health Organization, Disability – Fact Sheet, WHO Report, Geneva, 2023.

Editorial & Review Transparency

Publication Date

6/19/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

3

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...