Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM67659
Volume:
10 |
10 |
Oct 2026
Pages:
1-10
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Computer Science
Chikitsak Samuha’s S.S. & L.S. Patkar College of Arts & Science & V.P. Varde College of Commerce & Economics

Computer Science
Chikitsak Samuha’s S.S. & L.S. Patkar College of Arts & Science & V.P. Varde College of Commerce & Economics
Computer Science
Chikitsak Samuha’s S.S. & L.S. Patkar College of Arts & Science & V.P. Varde College of Commerce & Economics
Adapt-O Pillow is a prototype sensor-driven inflatable pillow that changes its support to suit the way a person is lying. The system integrates a chest-worn sensing unit, a main ESP32 controller, a pressure-feedback stage, a pneumatic actuator set, and a web interface for calibration and monitoring. An ESP32-C3 paired with an MPU6050 inertial sensor in the wearable unit determines body orientation and passes a stabilized orientation state to the main controller over Bluetooth. For each supported posture (back, left side, right side), the user records a preferred pillow pressure during a calibration routine. In automatic mode, an HX710B pressure-sensing interface reports the pillow's present pressure to the central controller, which compares it with the saved target. When the pressure is too low, the controller switches on the air pump and inlet solenoid valve; when it is too high, it opens the exhaust solenoid valve. A pressure tolerance band (deadband) together with orientation-stability filtering prevents needless actuator switching caused by minor pressure differences or brief body movements. The work is positioned as a prototype assistive comfort system and not as a medical diagnostic or treatment device. The project documentation covers functional implementation and qualitative behavior only; it contains no validated user study and no numerical figures for classification accuracy, pressure error, response time, battery endurance, or clinical outcome. This paper therefore concentrates on the architecture, control method, implementation, functional test approach, documented observations, limitations, and future development of the prototype.
KEYWORDS
Adapt-O Pillow presents a prototype architecture for an orientation-aware inflatable pillow that brings together wearable inertial sensing, Bluetooth communication, user calibration, pressure feedback, and pneumatic actuation. Its core idea is to turn a detected stable sleeping orientation into a personalized pressure target and then use closed-loop feedback to bring the pillow to that target. Posture recognition is thereby kept apart from low-level pressure regulation, giving a clear structure for step-by-step implementation and testing. The documented prototype integrates ESP32-C3/MPU6050 sensing, a main ESP32 controller, an HX710B pressure-feedback path, pump and solenoid-valve actuation, and a web application into a coherent whole. Filtering and deadband logic limit unnecessary changes, and conservative pressure limits with manual or emergency deflation are specified as safeguards. The system is deliberately presented as an assistive comfort prototype, not a medical device. The chief limitation of the present work is that no quantitative evaluation is documented. Future work should measure orientation-recognition performance, pressure-regulation behavior, communication reliability, energy use, and user-centered outcomes under controlled conditions. Such an evaluation would show how well the architecture performs beyond functional prototype operation.
[1] E. P. Doheny, M. M. Lowery, A. Russell, and S. Ryan, “Estimation of respiration rate and sleeping position using a wearable accelerometer,” in Proc. IEEE Eng. Med. Biol. Conf. (EMBC), 2020, pp. 4668–4671, doi: 10.1109/EMBC44109.2020.9176573. [2] C. -Y. Wang et al., “The relationship between sleeping position and sleep quality: A flexible sensor-based study,” Sensors, vol. 22, no. 16, Art. no. 6220, 2022. [3] H. Wang et al., “Smart pillow based on flexible and breathable triboelectric nanogenerator arrays for head movement monitoring during sleep,” ACS Appl. Mater. Interfaces, 2022. [4] H. Wang et al., “SleepSense: Smart pillow with pressure-sensitive FBG-embedded silicone buttons,” IEEE Sensors J., vol. 23, no. 17, pp. 19324–19331, 2023, doi: 10.1109/JSEN.2023.3295114. [5] Y. Lee et al., “Sleep pattern analysis in unconstrained and unconscious state,” Sensors, 2022. [Online]. Available: https://pmc.ncbi.nlm.nih.gov/articles/PMC9738183/ [6] A. Fu et al., “The effects of pillow designs on neck pain, waking symptoms, neck disability, sleep quality and spinal alignment in adults: A systematic review and meta-analysis,” Clin. Biomech., vol. 85, Art. no. 105353, 2021, doi: 10.1016/j.clinbiomech.2021.105353. [7] Y. Sun et al., “Personalized optimal pillow shape and pneumatic smart pillow maintaining natural cervical curvature: A pilot study,” Sci. Rep., 2026, doi: 10.1038/s41598-026-56415-7. [8] Espressif Systems, “ESP32 series datasheet,” Datasheet ver. 5.3, 2025. [Online]. Available: https://documentation.espressif.com/esp32_datasheet_e n.html [9] InvenSense, “MPU-6000 and MPU-6050 product specification,” Rev. 3.4, 2013. [Online]. Available: https://invensense.tdk.com/wp-content/uploads/2015/02/MPU-6000-Datasheet.pdf [10] S. M. Akif and M. M. Kaif, “Adapt-O Pillow: Project documentation,” Chikitsak Samuha's Patkar Varde College, M.Sc. Computer Science Part 2, 2026–2027.
Publication Date
10/5/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
2
Total views since publication
PDF Downloads
6
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...