Electronics & Communication Engineering
GNA University Phagwara
Computer Science Engineering
Lyallpur Khalsa College Technical Campus
Rapid urban development and growth of urban centres worldwide, combined with changing climate conditions have created an urgent need for improved environmental monitoring systems that are able to provide accurate assessment of environmental conditions in real-time. An Environmental Monitoring System based on the Internet of Things (IoT) is proposed in this paper, and it employs adaptive filtering techniques to increase accuracy of sensor data. The system combines inexpensive environmental sensors measuring air quality, temperature, humidity and light intensity. To reduce system noise and inaccuracies caused by the environment, a combination of adaptive filtering techniques (Least Mean Squares (LMS) and Kalman filters), will be applied to sensor data at the point where measurements are made. The main contribution made by this work is the development of a Hybrid Adaptive Filter (HAF) that automatically switches between the use of LMS and Kalman filtering based on real-time variance of the input signal to achieve improved noise reduction (i.e., mean square error reduction of 58%, signal-to-noise ratio increase of 15 dB) while maintaining negligible additional power consumption. A new Environmental Health Index (EHI) is also proposed to create an actionable score from all the different sensors collecting data on multiple parameters. To demonstrate the success of these techniques, experiments over 14 days were conducted at five geographically dispersed urban sites, and data indicate that both techniques are effective in reducing noise (improved reliability of collected data), and improving both sensor and power efficiency for IoT systems. This work creates a pathway to the development of scalable, thermally and energy-efficient environmental monitoring systems, which may support smart cities, agriculture, and industrial operations.
KEYWORDS
In this study, we developed a proof-of-concept IoT-based Environmental Monitoring System (EMS) using adaptive filtering methods to improve the quality of the collected signals. The EMS contains inexpensive air quality, temperature, humidity, light level sensors interfaced to an ESP32 microcontroller along with cloud-based analytics, and was tested over 14 consecutive days in a variety of locations across five different urban environments. The primary innovation is a new algorithm called the HAF which demonstrated improvements in signal quality over every measure when compared to a single, unfiltered measurement as well as compared with independent signal processing methods such as Kalman (which showed 38%-45% improvements in MSE and 8-12 dB improvements in SNR) and LMS filters (which showed 25%-30% improvements in MSE and 6-8 dB improvements in SNR). In addition, HAF's mode-switching feature proved particularly beneficial at high variability sites (up to 65% improvement in MAE at the industrial site). The new EHI developed using HAF processed multiple sensor data streams into one composite score which was validated against the regulatory AQI (r = 0.89, p < 0.001). This represents the first time a composite environmental index based on adaptive-filtered signals from IoTs has been developed within the literature. Analysis of the diurnal and site-stratified datasets show that HAF mode-switching behaviors follow clearly intuitive environmental patterns and confirm that the algorithm is effectively detecting and adapting to signal regime changes across a wide variety of urban settings, as intended. All filtering configurations were found to have negligible impacts on the battery life of the system (i.e., maximum 5-day loss from the normal estimated 37–42-day cycle) and demonstrated acceptable real-time latency when processing data (i.e., maximum 3.9 ms), suggesting they can be practically deployed on resources-limited embedded systems. Overall, the results from this study suggest that there is sufficient evidence to support the claim that utilizing low-cost IoT sensing technologies in conjunction with adapted signal processing, principles of composite index health monitoring, and consistent accuracy allows for reasonably comparable accuracy and intelligibility when developing large-scale environmental monitoring systems; thus, allowing for the development of dense metropolitan-scale monitoring networks to address 21st century air quality and climate issues.
[1] L. Zhang and J. Zhang, “IoT-enabled air quality monitoring and filtering for urban areas,” Sensors, vol. 19, no. 7, p. 1662, 2019. [2] A. Kumar, P. Singh, and R. Kumar, “Noise characterization and compensation in low-cost IoT environmental sensors,” IEEE Sensors Journal, vol. 21, no. 14, pp. 15820–15831, 2021. [3] H. Li, W. Chen, and X. Zhou, “Adaptive signal processing for IoT sensor networks: A survey,” IEEE Communications Surveys & Tutorials, vol. 23, no. 2, pp. 1025–1058, 2021. [4] B. Widrow and S. D. Stearns, Adaptive Signal Processing. Englewood Cliffs, NJ: Prentice-Hall, 1985. [5] I. F. Akyildiz, W. Su, Y. Sankarasubramaniam, and E. Cayirci, “Wireless sensor networks: A survey,” Computer Networks, vol. 38, no. 4, pp. 393–422, 2002. [6] U. Raza, P. Kulkarni, and M. Sooriyabandara, “Low power wide area networks: An overview,” IEEE Communications Surveys & Tutorials, vol. 19, no. 2, pp. 855–873, 2017. [7] A. McEwen and H. Cassimally, Designing the Internet of Things. Chichester, UK: Wiley, 2014. [8] S. M. Kay, Fundamentals of Statistical Signal Processing: Estimation Theory. Englewood Cliffs, NJ: Prentice Hall, 1993. [9] M. Snyder et al., “The changing paradigm of air pollution monitoring,” Environmental Science & Technology, vol. 47, no. 20, pp. 11369–11377, 2013. [10] E. Spinelle et al., “Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring,” Sensors and Actuators B: Chemical, vol. 215, pp. 249–257, 2015.
Publication Date
6/11/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
4
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...