Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM67141

Assessment of Indoor Air Quality and Associated Health, Environmental and Social Risks in Academic Laboratories of Educational Institutions

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM67141

Volume:

10 |

9 |

Sep 2026

Pages:

1-17

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM67141

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

KM

KEERTHIKA M

Environmental Engineering

Government college of technology,Coimbatore

Download Author Certificate
RK

Rajeshkumar Kadarkarai

Environmental Engineering

Government college of technology,Coimbatore

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Nowadays Indoor Air Quality (IAQ) has become a growing concern due to increased indoor activities, combustion processes, and poor ventilation. Testo IAQ Sensor Kit has been used to focus on monitoring and evaluation of IAQ across five laboratories (Thermal, Welding, Carpentry, Chemical, and Concrete) at GCT, Coimbatore. Monitoring has been done during September (60–80% RH) and October (81–93% RH). Weekly variations with respect to humidity were assessed, and comparison between September and October were made. To assess overall air quality and pollutant levels in each laboratory, Indoor Air Quality Index (IAQI) was calculated. It was found that Pollutant concentrations have been increased in October compared to September with rising humidity, except for CO, which decreased due to enhanced oxidation. Due to the absence of combustion activities, CO emissions were negligible in the Concrete, Carpentry, and Chemical labs. The Thermal Lab recorded the highest pollutant levels, followed by Carpentry, Concrete, Chemical, and Welding. Pollutant dominance followed the order PM₂.₅ (932 µg/m³) > TVOC (8.303 mg/m³) > HCHO (3.404 mg/m³) > CO₂ (790 ppm) > CO (301 ppm), identifying PM₂.₅ as the most critical pollutant. According to IAQI results, the worst air quality was found in the Thermal Lab (≈500, hazardous), followed by Carpentry (≈460), Concrete (≈410), Chemical (≈370), and Welding (≈320). The impact of IAQI came after PM₂.₅ > TVOC > HCHO > CO₂ > CO. IAQ considerably worsened from September to October due to increased humidity, with thermal lab being the most affected and PM2.5 as the main pollutant highlighting the necessity of adequate ventilation, humidity control, and routine IAQ monitoring. Subsequently, health risk, environmental risk and social impact assessments were also carried out with recommendations for proper mitigation measures

KEYWORDS

Indoor air quality IAQI; carbon monoxide (CO); carbon dioxide (CO₂); Formaldehyde (HCHO); Total volatile organic compounds (TVOC); Particulate matter (PM₂.₅); Health risk assessment; Environmental impact and social impact assessment

Cite This Article

KEERTHIKA M, Rajeshkumar Kadarkarai, "Assessment of Indoor Air Quality and Associated Health, Environmental and Social Risks in Academic Laboratories of Educational Institutions," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 9, pp. 1-17, Sep 2026. https://doi.org/10.55041/IJSREM67141

Full Article/Conclusion

The project titled “Assessment of Indoor Air Quality at GCT, Coimbatore” highlights how air quality varied across different campus laboratories and how environmental conditions influenced pollutant levels. The study found that pollutant concentrations increased in October compared to September, mainly due to rising humidity, while carbon monoxide (CO) levels decreased because of enhanced oxidation. CO emissions were negligible in the Concrete, Carpentry, and Chemical labs due to the lack of combustion activities. Among all spaces, the Thermal Lab showed the highest pollutant levels, followed by Carpentry, Concrete, Chemical, and Welding labs. The pollutants ranked in dominance as PM₂.₅ (932 µg/m³) > TVOCs (8.303 mg/m³) > formaldehyde (3.404 mg/m³) > CO₂ (790 ppm) > CO (301 ppm), identifying PM₂.₅ as the most critical pollutant. According to the Indoor Air Quality Index (IAQI), the Thermal Lab had the poorest air quality (≈500, hazardous), followed by Carpentry (≈460), Concrete (≈410), Chemical (≈370), and Welding (≈320). Overall, air quality worsened from September to October due to higher humidity, with PM₂.₅ being the main contributor to poor IAQ. The findings emphasize the urgent need for better ventilation, humidity control, and regular indoor air quality monitoring to maintain a healthier indoor environment. IAQI values revealed hazardous conditions in several laboratories, especially the Thermal and Carpentry units, underscoring the need for improved ventilation strategies, pollutant source control, and real-time IAQ surveillance. The study’s outcomes align closely with global IAQ research trends in educational and laboratory environments [1]–[20], reinforcing the importance of humidity-aware IAQ management to safeguard occupant health and ensure safe learning conditions. To overcome the aforementioned problems, it is necessary to have a comprehensive solution to mitigate them based on the requisite control systems for environmental issues, therefore developing specialized laboratory environments. The lab environments include implementing additional air intake/exhaust systems in thermal and welding labs; dust and VOC (volatile organic compounds) controls in carpentry labs; containment of chemicals during chemical lab processing; dust suppression techniques used during concrete labs operation; and utilizing health related issues ie; more exposure management and use of personal protection equipment (PPE). Finally support for social initiatives should also be procured through PA research and educational programmes on workplace safety, as well as using technology such as real-time Indoor Air Quality (IAQ) monitoring and improved work environments as means to provide support to the laboratories.

References

[1]  Thongsumrit, J., et al., “Indoor air quality assessment to design a model for indoor air quality management and health impact assessment in Northern Thailand,” E3S Web of Conferences, vol. 396, p.01096,2023. https://doi.org/10.1051/e3sconf/202339601096 [2]  Mahnoor, Fernando, N. G., & Rathnaweera Patabandige, H. S. B., “The Impact of Indoor Air Quality in Higher Education Institutions,” in Concepts, Policies and Technology for Sustainable Buildings,Springer,2025,pp.239–258. https://doi.org/10.1007/978-981-96-3086-8_12 [3]  Onat, B., et al., “Indoor environmental quality in the university laboratories,” Pamukkale University Journal of Engineering Sciences, vol. 29, no. 6, pp. 642–649, 2023. https://doi.org/10.5505/pajes.2022.37941 [4]  Saad, S. M., et al., “Development of indoor environmental index: Air quality index and thermal comfort index,” AIP Conference Proceedings, vol. 1808, no. 1, 020043, 2017. https://doi.org/10.1063/1.4975276 [5]  Sudarsan, J. S., et al., “Assessment on the impact of indoor air quality on human health—a study on selected tier 1 cities of India,” Discover Environment, vol. 2, no. 1, p. 142, 2024. https://doi.org/10.1007/s44274-024-00164-9 [6]  Sesena, S., et al., “Indoor air quality analysis in naturally ventilated university training laboratories: a health risk assessment,” Air Quality, Atmosphere & Health, vol. 15, no. 10, pp. 1817–1837, 2022. https://doi.org/10.1007/s11869-022-01220-0 [7]  Branco, P. T., et al., “A review of relevant parameters for assessing indoor air quality in educational facilities,” Environmental Research, vol. 261, p. 119713, 2024. https://doi.org/10.1016/j.envres.2024.119713 [8]  Sugumar, P., et al., “Investigation of Indoor Air Quality and Thermal Comfort of a College Building in Hyderabad, India,” IOP Conf. Ser.: Earth Environ. Sci., vol. 1074, p. 012025, 2022. https://doi:10.1088/1755-1315/1074/1/012025 [9]  Ismail, I. F., et al., “Indoor air quality (IAQ) in educational institutions: a review on risks of poor IAQ, sampling strategies, and building-related health symptoms,” Journal of Safety, Health & Ergonomics, vol. 2, no. 1, 2020. [10]  Jung, C., et al., “Indoor air quality in educational institutions: a comparative study of VOCs and bacterial contaminants in Dubai schools,” Frontiers in Built Environment, vol. 10, p. 1478681, 2024. https://doi.org/10.3389/fbuil.2024.1478681

Editorial & Review Transparency

Publication Date

9/7/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

7

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles