Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM67936

Automatic Standby Generator Changeover Simulator using delta DVP12SA2 PLC

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM67936

Volume:

10 |

10 |

Oct 2026

Pages:

1-8

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM67936

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

Neha Santosh Solapure

Neha Santosh Solapure

Electronic & Telocommunication engineering

Bhivrabai Sawant polytechnic Wagholi pune

Download Author Certificate
Sharvari Ramesh Salunkhe

Sharvari Ramesh Salunkhe

Electronic & Telocommunication engineering

Bhivrabai Sawant polytechnic Wagholi pune

Download Co-Author Certificate
Tanuja Raghunath Shelke

Tanuja Raghunath Shelke

Electronic & Telocommunication engineering

Bhivrabai Sawant polytechnic Wagholi pune

Download Co-Author Certificate
Shreyash Vikas Urade

Shreyash Vikas Urade

Electronic & Telocommunication engineering

Bhivrabai Sawant polytechnic Wagholi pune

Download Co-Author Certificate
WMN

Waghmode M. N.

Electronic & Telocommunication engineering

Bhivrabai Sawant polytechnic Wagholi pune

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

The Automatic Standby Generator Changeover Simulator is a PLC-based automation system designed to demonstrate the automatic transfer of a simulated electrical load between the main power supply and a standby generator. The proposed system addresses the need for reliable power continuity by replicating common supply failure and (PLC)monitors the simulated mains status andgenerator readiness through digital input devices. According to the programmed logic, it controls relay interfaces and visual indicators to represent the selection of the appropriate power source. The system also incorporates Auto/Manual mode selection, Start/Stop controls, fault indication, and an optional LCD display for improved monitoring.

KEYWORDS

Automatic Changeover Standby Generator Power Supply Management Industrial Automation Relay Interlocking.

Cite This Article

Neha Santosh Solapure, Sharvari Ramesh Salunkhe, Tanuja Raghunath Shelke, Shreyash Vikas Urade, Waghmode M. N., "Automatic Standby Generator Changeover Simulator using delta DVP12SA2 PLC," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 10, pp. 1-8, Oct 2026. https://doi.org/10.55041/IJSREM67936

Full Article/Conclusion

The Automatic Standby Generator Changeover Simulator using the Delta DVP12SA2 PLC provides an effective platform for understanding automatic power transfer and industrial automation principles. The system demonstrates how a PLC monitors simulated mains supply conditions, verifies generator readiness, and controls source-selection indicators according to predefined logic. The integration of input switches, relay interfaces, indicator lamps, and fault alarms supports practical learning of PLC programming, sequential control, and input-output interfacing. The simulator offers a cost-effective and safer alternative for laboratory demonstrations because it represents power-source conditions using low-voltage components. Its modular design also allows future enhancements, including voltage monitoring, programmable time delays, event logging, and remote status indication. Overall, the project strengthens practical engineering skills and provides a foundation for studying advanced automatic transfer systems.

References

2.   Delta Electronics: DVP-SA2 Series Programmable Logic Controller: Product Specifications and Technical Information. Delta Electronics. Source.3.     International Electrotechnical Commission (IEC): Programmable Controllers—Part 1: General Information. IEC 61131-1. Consult the IEC catalogue for the applicable edition.4.     International Electrotechnical Commission (IEC): Programmable Controllers—Part 3: Programming Languages. IEC 61131-3. Consult the IEC catalogue for the applicable edition.5.      International Electrotechnical Commission (IEC): Low-voltage Switchgear and Controlgear—Part 5-1: Control Circuit Devices and Switching Elements—Electromechanical Control Circuit Devices. IEC 60947-5-1. Consult the applicable edition.6.      International Electrotechnical Commission (IEC): Low-voltage Switchgear and Controlgear—Part 2: Circuit-breakers. IEC 60947-2. Consult the applicable edition.2. DeltaElectronics: DVP-PLC Application Manual: Programming and Instruction Reference. Delta Electronics. Refer to the manual corresponding to the installed PLC model.3.     Delta Electronics: ISPSoft Programming Software User Manual. Delta Electronics. Refer to the official documentation for the software version used.4.       International Organization for Standardization (ISO): Quality Management Systems—Fundamentals and Vocabulary. ISO 9000. Consult the applicable edition for terminology relevant to quality and system documentation.5.         International Electrotechnical Commission (IEC): Low-voltage Electrical Installations—Protection for Safety. Consult the applicable IEC 60364 parts for installation and protection principle

Editorial & Review Transparency

Publication Date

10/19/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

1

Total views since publication

PDF Downloads

6

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...