Department of Civil Engineering
Deccan College of Engineering and Technology
Department of Civil Engineering
Deccan College of Engineering and Technology
Department of Civil Engineering
Deccan College of Engineering and Technology
Department of Civil Engineering
Deccan College of Engineering and Technology
This study presents a comparative seismic evaluation of a G+20 storey reinforced concrete (RC) building in Seismic Zone V, Gujarat, under three configurations: a fixed-base system (Model A), a base-isolated system using pure rubber bearings (Model B), and a hybrid system combining base isolation with X-type steel bracing at Storeys 17-20 (Model C). Three-dimensional models were analysed under Equivalent Static Analysis (ESA), Response Spectrum Analysis (RSA), and Non-Linear Time History Analysis (NLTHA) using five spectrum-compatible ground motions, per IS 1893 (Part 1): 2016. Modal analysis showed only marginal period elongation under isolation (1.511 s to 1.521 s), so Models A and B recorded nearly identical NLTHA roof displacements (130.28 mm), exceeding the H/500 = 120 mm limit; isolation alone yielded modest base-shear (0.98-2.03%) and drift (3.9%) reductions. ESA over-predicted and RSA under-predicted the NLTHA demand, confirming NLTHA as essential for reliable assessment. The hybrid configuration (Model C) reduced peak roof displacement to 117.56 mm (9.8% reduction, H/500-compliant) and critical inter-storey drift by 44.1%, at an 11.7% base-shear increase relative to Model B. These findings were corroborated by a supplementary pushover and Incremental Dynamic Analysis (IDA) study, confirming that isolation shifts the governing limit state from superstructure collapse (Model A, 0.40 g) to isolator displacement capacity (Models B and C, 0.08 g). The study concludes that the hybrid base-isolation-with-bracing system alone satisfies the drift limit, the H/500 criterion, and a net base-shear reduction relative to the fixed-base design, establishing it as an effective seismic protection strategy for tall RC buildings in high-seismic zones.
KEYWORDS
1. ESA, RSA and NLTHA were performed on 3-D ETABS models of Models A and B per IS 1893 (Part 1): 2016. Peak roof displacement rose from 30.79-31.52 mm (RSA) to 130.28 mm (NLTHA, Model A), with a non-monotonic storey-shear profile (peak at Storey 10, 64% of base shear) reflecting higher-mode effects that ESA and RSA do not capture; the maximum drift ratio (0.00284) remained within the IS 1893 limit of 0.004 under all methods, confirming code compliance but establishing NLTHA as essential for this building class. 2. The fundamental period elongated only marginally, from 1.511 s (Model A) to 1.521 s (Model B, +0.66%), well short of the three- to four-fold elongation expected of effective isolation; modal mass participation (66.54-66.65% at Mode 1) was essentially unchanged, indicating energy dissipation remained governed by superstructure hysteresis rather than isolator damping. 3. Base isolation reduced NLTHA base shear by only 0.98-2.03% and drift by 3.9% relative to Model A, while peak roof displacement stayed unchanged at 130.28 mm - isolation redistributes demand to the isolator level rather than reducing it, lowering member-level damage but leaving global displacement demand essentially unaddressed. 4. Models A and B both exceed the H/500 = 120 mm limit at 130.28 mm; Model C reduces this to 117.56 mm (9.8% reduction, H/500-compliant) and cuts critical drift by 44.1%, at an 11.7% base-shear cost relative to Model B. The supplementary pushover/IDA study confirms this pattern: Model A reaches Collapse Prevention drift at 0.40 g, while Models B/C are isolator-governed, reaching their 200 mm design displacement at a much lower, tightly clustered 0.08 g, with superstructure drift held well below Immediate Occupancy. 5. Model C is the only configuration to satisfy both the drift and H/500 criteria while reducing base shear relative to the fixed-base case, establishing the hybrid isolation-plus-bracing strategy as the recommended configuration for tall RC buildings in high-seismic zones such as Gujarat, Seismic Zone V.
[1] Bhandari, M., Singh, H., Bharti, S., & Shrimali, M.K. (2025). Influence of characteristics of lead rubber bearing isolator on the seismic response of a base-isolated building. Journal of Structural Design and Construction Practice, ASCE, 30(3). https://doi.org/10.1061/JSDCCC.SCENG-1737 [2] Hasanoglu, M., et al. (2024). Optimal selection and scaling of ground motion records compatible with input energy and acceleration spectra. Earthquake Engineering and Structural Dynamics, Wiley. https://doi.org/10.1002/eqe.4114 [3] Miao, Z., et al. (2024). A response-compatible ground motion generation method using physics-guided neural networks. Computer-Aided Civil and Infrastructure Engineering, Wiley. https://doi.org/10.1111/mice.13194 [4] Patel, V., et al. (2024). Advancements in base isolation for seismic mitigation. Research on Engineering Structures and Materials, 10(3), 1017-1049. [5] Raghukanth, S.T.G., et al. (2024). Spectrum-compatible ground motion database for important urban centers in India. Journal of Earth System Science, Springer, 133. https://doi.org/10.1007/s12040-025-02712-0 [6] Benaoum, F., Moussaoui, M., & Tidjani, M. (2023). Enhancing the seismic response of residential RC buildings with an innovative base isolation technique. Sustainability, MDPI, 15(15), 11624. https://doi.org/10.3390/su151511624 [7] Furtado, A., Rodrigues, H., & Arêde, A. (2022). Inter-story seismic isolation for high-rise buildings. Engineering Structures, 275. https://doi.org/10.1016/j.engstruct.2022.115175 [8] Khoury, W., Kobaissy, A., & Ghanem, H. (2021). Effect of lead-rubber bearing isolators in reducing seismic damage for a high-rise building in comparison with normal shear wall system. Structural Durability and Health Monitoring, 15(3). https://doi.org/10.32604/sdhm.2021.016651 [9] Ghasemi, M., & Talaeitaba, S.B. (2020). On the effect of seismic base isolation on seismic design requirements of RC structures. Structures, 28, 2244-2259. https://doi.org/10.1016/j.istruc.2020.09.063 [10] Rahimi, A., & Maheri, M.R. (2020). The effects of steel X-brace retrofitting of RC frames on the seismic performance of frames and their elements. Engineering Structures, 206, 110149. https://doi.org/10.1016/j.engstruct.2019.110149
Publication Date
8/11/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...