Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM68941
Volume:
10 |
11 |
Nov 2026
Pages:
1-8
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Department of Civil Engineering
Sanketika Vidya Parishad Engineering College, P.M. Palem, Visakhapatnam – 530041, Andhra Pradesh, India
Department of Civil Engineering
Sanketika Vidya Parishad Engineering College, P.M. Palem, Visakhapatnam – 530041, Andhra Pradesh, India
The plan configuration of reinforced concrete (RCC) buildings influences lateral stiffness distribution, seismic-force transfer and torsional response. This study compares a regular rectangular symmetric G+10 RCC frame with an L-shaped asymmetric G+10 frame under earthquake loading corresponding to Seismic Zones III and IV. Both models have a nominal plan envelope of 24 m × 18 m, the same storey arrangement, material grades and support assumptions. The comparison considers roof displacement, inter-storey drift, base shear, support reactions, column axial force, beam and column bending moments, and qualitative torsional behavior. In the principal result set, the maximum roof displacements in the X direction are 34.6 and 51.7 mm for the symmetric building in Zones III and IV, respectively, compared with 43.8 and 65.4 mm for the asymmetric building. Maximum storey drift increases from 3.36 to 4.32 mm in Zone III and from 5.04 to 6.51 mm in Zone IV when the plan configuration changes from symmetric to asymmetric. Beam and column moments are also higher in the asymmetric model, with the largest reported values of 296 kN·m and 508 kN·m in Zone IV. The results indicate that plan asymmetry is associated with greater deformation and local member-force concentration. For several response parameters, the Zone IV values are approximately 50% higher than the corresponding Zone III values. The numerical response quantities are representative estimates based on assumed building models and require replacement or confirmation using final STAAD.Pro analysis outputs. The findings are therefore interpreted as indicative comparative results rather than validated design outputs.
KEYWORDS
The comparative results indicate that plan configuration is an important factor governing the seismic response of G+10 RCC frames. Under the adopted assumptions and representative response values, the symmetric rectangular building exhibits a more uniform response, whereas the L-shaped asymmetric building shows higher displacement, drift, member moments and torsional demand. The differences are most pronounced in Zone IV. The lower reported base shear of the asymmetric building should not be interpreted as evidence of superior seismic performance because its local force demands and deformation measures are higher. Where an irregular plan is unavoidable, design attention should be directed to torsion, re-entrant corners, corner columns, beam–column joints, stiffness distribution and ductile detailing. The comparative results support the preference for regular plans where architectural and functional requirements permit.
[1] Bureau of Indian Standards, IS 1893 (Part 1):2016, Criteria for Earthquake Resistant Design of Structures—Part 1: General Provisions and Buildings, New Delhi, India. [2] Bureau of Indian Standards, IS 456:2000, Plain and Reinforced Concrete—Code of Practice, New Delhi, India. [3] Bureau of Indian Standards, IS 875 (Part 1), Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures—Dead Loads, New Delhi, India. [4] Bureau of Indian Standards, IS 875 (Part 2), Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures—Imposed Loads, New Delhi, India. [5] Bureau of Indian Standards, IS 13920, Ductile Design and Detailing of Reinforced Concrete Structures Subjected to Seismic Forces, New Delhi, India. [6] Bentley Systems, STAAD.Pro Structural Analysis and Design Software Documentation. [7] G. G. Kakpure and A. R. Mundhada, “Comparative Study of Static and Dynamic Seismic Analysis of Multistoried RCC Buildings,” International Journal of Engineering Research, 2016. [8] S. Dubey, P. Sangamnerkar, and A. Agrawal, “Dynamics Analysis of Structures Using Response Spectrum Method,” 2015. [9] P. Akhil and Aswathy Kumar, “Seismic Analysis of Regular and Irregular Buildings with Vertical Irregularity Using STAAD.Pro,” 2017. [10] A. J. Satheesh, B. R. Jayalekshmi, and K. Venkataramana, “Effect of In-Plan Eccentricity on Vertically Stiffness Irregular Buildings under Earthquake Loading,” Soil Dynamics and Earthquake Engineering, 2020.
Publication Date
11/13/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
2
Total views since publication
PDF Downloads
5
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...