Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM66660

Comparative Study of a Conventional Bridge and a Cable-Stayed Bridge Using STAAD.Pro

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM66660

Volume:

10 |

8 |

Aug 2026

Pages:

1-12

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM66660

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

SSS

Sumit Sarjerao Shinde

Department of Civil Engineering

Deogiri Institute of Engineering and Management Studies, Chhatrapati Sambhajinagar, Maharashtra, India

Download Author Certificate
A

Anil.B.Wakankar

Department of Civil Engineering

Deogiri Institute of Engineering and Management Studies, Chhatrapati Sambhajinagar, Maharashtra, India

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Selecting between a conventional reinforced-cement-concrete (RCC) bridge and a cable-stayed bridge requires an evidence-based comparison of load-transfer mechanism, force demand, and dynamic behaviour rather than a judgment based on span length alone. This study presents a finite-element-based comparative assessment of two STAAD.Pro models: a continuous RCC deck-girder bridge and a long-span cable-stayed bridge, both verified at an overall longitudinal length of 541.8 m. The RCC model comprises seven spans of 72.914 m and one span of 31.5 m, a 250 mm deck slab over three girders spaced at 3.75 m centres, M30 concrete and Fe500 reinforcement. The cable-stayed model has a 285.6 m main span and two 128.1 m side spans, a 14.20 m deck carried by two H-frame pylons and eighty semi-harp stay cables. Structural response was extracted for bending moment, shear force, support reaction, member-end forces, and modal characteristics. The RCC bridge returned a maximum bending moment of 14,890 kN·m, maximum shear of 2,180 kN, total vertical reaction of 16,860 kN, and a first-mode frequency of 1.295 Hz (period 0.772 s). The cable-stayed bridge returned a maximum bending moment of 67,356.56 kN·m, maximum shear of 5,778.45 kN, a self-weight vertical reaction of approximately 181,000 kN, and a far more flexible first-mode frequency of 0.09 Hz (period 11.16 s). Raw percentage differences of 352.36%, 165.07%, and 973.55% respectively reflect the far greater length, deck area, and concentrated pylon load path of the cable-stayed system rather than structural inefficiency. The results confirm that the RCC form remains the rational choice for medium, multi-support crossings, while the cable-stayed form is structurally justified only where an unobstructed long span is the governing requirement.

KEYWORDS

RCC Bridge; Cable-Stayed Bridge; STAAD.Pro; Finite Element Analysis; Comparative Structural Analysis; Modal Analysis; Bending Moment and Shear Force

Cite This Article

Sumit Sarjerao Shinde, Anil.B.Wakankar, "Comparative Study of a Conventional Bridge and a Cable-Stayed Bridge Using STAAD.Pro," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 8, pp. 1-12, Aug 2026. https://doi.org/10.55041/IJSREM66660

Full Article/Conclusion

•            Both STAAD.Pro models were verified at an equal overall length of 541.8 m, allowing structural differences to be attributed to load-transfer mechanism rather than length mismatch. •            The RCC bridge, arranged as seven 72.914 m spans plus one 31.5 m span, produced a maximum bending moment of 14,890 kN·m, maximum shear of 2,180 kN, and total vertical reaction of 16,860 kN. •            The cable-stayed bridge, with a 285.6 m main span and two 128.1 m side spans, produced a maximum bending moment of 67,356.56 kN·m, maximum shear of 5,778.45 kN, and a self-weight vertical reaction of approximately 181,000 kN. •            Raw percentage differences of 352.36% (bending moment), 165.07% (shear), and 973.55% (reaction) are consequences of the cable-stayed bridge's much larger tributary deck area concentrated at fewer support points, not evidence of structural inefficiency. •            Modal results show the RCC bridge is a stiff, short-period system (first mode 1.295 Hz, 0.772 s) while the cable-stayed bridge is a flexible, long-period system (first mode 0.09 Hz, 11.16 s), consistent with the general dynamic character of cable-supported long-span structures reported in the literature. •            The RCC bridge's reported mid-span deflection of 32.5 mm remains within its stated 50 mm serviceability limit; an equivalent cable-stayed deflection value could not be obtained from the source data. •            Global load-reaction equilibrium was independently verified for the cable-stayed self-weight case, confirming model stability for that load case. •            The RCC bridge is the structurally and economically rational choice for a medium-span, multiply-supported crossing of this type, while the cable-stayed configuration is justified specifically where a single, unobstructed 285-290 m span is a governing requirement (navigation clearance, obstacle-free crossing). •            No single "optimum" system emerges from raw force comparison alone; bridge-type selection must weigh span requirement, foundation conditions, construction capability, and life-cycle maintenance alongside the force magnitudes reported here. •            From a sustainability and material-use standpoint, the cable-stayed system achieves a substantially longer unsupported span per unit of foundation footprint, which is significant where minimising in-water or in-ground disturbance is a design priority, although a formal material-quantity or embodied-carbon comparison was outside the scope of the available data.

References

[1]        Abdelaziz, M. M., El-Ghazaly, H. A., & Gomaa, M. S. (2024). Numerical modeling for collapse analysis of cable-stayed bridges using the improved applied element method. Iranian Journal of Science and Technology, Transactions of Civil Engineering, 48, 2891-2904. [2]        Fan, Q., Yang, Z., Yang, Z., Ma, C., Wang, J., & Liu, J. (2025). Optimization of cable forces of completed asymmetric hybrid-girder cable-stayed bridge with fish-shuttle-shaped single tower based on MIDAS Civil. Atlantis Highlights in Engineering, 37, 213-227. [3]        Fawzy, A. M., El-Kashif, K. F., & Abdalla, H. A. (2022). Seismic performance of cable-stayed bridges with different geometric conditions. Journal of Engineering and Applied Science, 69, Article 82. [4]        Galar, N., & Pahwa, S. (2025). Review - Seismic analysis of cable-stayed bridge under moving loads using IRC and AASHTO methods with different shapes of pylons. International Journal of Advanced Scientific Research and Engineering Trends, 9(7), 38-42. [5]        Gao, L., Liu, Z., Dai, F., & Chen, J. (2024). Response analysis of a long-span cable-stayed bridge with ultra-high piles subjected to near-fault ground motions. Advances in Bridge Engineering, 5, Article 34. [6]        Hassan, M. M., Annan, C. D., & Norlander, G. W. (2012). Optimal design of stay cables in cable-stayed bridges. Proceedings of the 3rd International Structural Specialty Conference, 2140-2149. [7]        Janbandhu, N. K., & Gaikwad, S. (2018). Study and analysis of cable stayed bridges using STAAD.Pro. Journal of Emerging Technologies and Innovative Research, 5(9), 260-264. [8]        Kallingal, S. S., & Singh, P. (2021). Dynamic analysis of cable-stayed bridge with various patterns of pylon. E3S Web of Conferences, 304, Article 02005. [9]        Khan, A., & Akhtar, S. (2023). Structural analysis of cable-stayed bridge with different shape of pylon using STAAD.Pro. International Journal of Science, Engineering and Technology, 11(4), 1-9. [10]       Klusáček, L., Nečas, R., Koláček, J., Bezručová, K., & Vašinová, M. (2026). Cable-stayed bridges, diagnostic survey of stays. Civil and Environmental Engineering, 22(1), 332-345.

Editorial & Review Transparency

Publication Date

8/10/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

2

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...