A comparative study of structural design (by staadpro software) of two storeyed residential building in earthquake zone II and V has been done. A two storeyed residential building has been taken for comparison. The building consists of two floors (Ground floor and first floor). The ground floor consists of verandah, drawing room, dining hall, kitchen, one bedroom, two toilets and a staircase. The first floor consists of two balconies, three bedrooms, three toilets, a study room and staircase. The second floor will be terrace floor with mumty for staircase. The structure of the building has been analysed using the staadpro software of version STAAD.Pro CONNECT Edition V22. Two models of the same building have been developed. One model has been analysed for earthquake zone II and second model has been analysed for earthquake zone V. A comparative study of the design results of beams and columns has been made. A summary conclusion has been arrived at.
KEYWORDS
1. Reinforcement required for the building in zone II is always less that the reinforcement requirement for the building in zone V. 2. Minimum ratio of reinforcements required for columns from footing to ground level is 4.94 and maximum ratio is 11.59. 3. Minimum ratio of reinforcements required for Columns from ground level to first floor level is 5.75 and maximum ratio is 14.18. 4. Minimum ratio of reinforcements required for Columns from first floor level to second floor level is 3.07 and maximum ratio is 11.99. 5. Minimum ratio of reinforcements required for columns from second floor level to mumty roof level is 3.47 and maximum ratio is 10.58. 6. Ratio of zone factor is 3.60. But ratios of reinforcements are not in the same pattern. Hence any rational conclusion could not be made.
1. IS 456-2000: - Plain and reinforced concrete -code of practice 2. IS 875 Part 1-1987: -Code of practice for design loads (other than earthquake) for buildings and structures part 2 imposed loads 3. IS 875 Part 2-1987: -Code of practice for design loads (other than earthquake) for buildings and structures part 2 imposed loads dead loads -unit weights of building materials and stored materials 4. IS 1893 Part 1-2016: - Criteria for earthquake resistant design of structures part 1 General provisions and building 5. IS 1786-2006: - High strength deformed steel bars and wires for Concrete Reinforcement – specification 6. Design of reinforced concrete structures: - S. Ramamrutham 7. Concrete structures: - V.N. Vazirani & M.M. Ratwani
Publication Date
5/18/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...