Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM67759
Volume:
10 |
10 |
Oct 2026
Pages:
1-5
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Computer Engineering
PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune
Computer Engineering
PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune
Computer Engineering
PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune
Computer Engineering
PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune
Timely mass screening for cataract and anemia is obstructed in low-resource settings by the cost and expertise demands of slit-lamp biomicroscopy and laboratory hemoglobin assays. This paper describes a dual-disease ocular screening system comprising two independent convolutional neural network pipelines integrated within a single Flask-based web application. Cataract detection employs EfficientNet-B0 fine-tuned on 4,081 eye images (1,066 normal, 3,015 cataract) with automatically computed inverse-frequency class weights and a two-phase training schedule: head-only optimization at a learning rate of 1×10⁻³ followed by selective backbone unfreezing at 1×10⁻⁶. Anemia screening employs MobileNetV3-Small trained on 988 conjunctival images (388 anemia-positive, 600 controls) with the final 30 backbone layers unfrozen, a fixed class weight of 1.5× on the minority class, and Adam optimization at 1×10⁻⁴. Both models are served at 224×224 pixel input resolution with runtime augmentation and confidence-threshold gating. On held-out test partitions, the anemia module achieved 87.50% accuracy with an AUC of 0.9023, and the cataract module achieved 83.46% validation accuracy with an AUC of 0.8992; the observed gap between validation and independent test performance for the cataract task is analyzed as a function of dataset size and acquisition heterogeneity. The deployed application supports PNG, JPG, and BMP input, executes inference in sub-second latency, and generates structured PDF screening reports, establishing a technically complete prototype for point-of-care ocular triage in resource-limited environments.
KEYWORDS
This paper presented the design, training, and deployment of a dual-pipeline ocular screening system pairing EfficientNet-B0 for cataract classification with MobileNetV3-Small for conjunctival anemia detection. The anemia module achieved 87.50% accuracy and an AUC of 0.9023 on a held-out test partition, with zero false positives recorded — a performance profile consistent with published single-disease anemia classifiers and sufficient to justify continued development toward clinical validation. The cataract module achieved 83.46% validation accuracy, an AUC of 0.8992, and a recall of 0.9768 on the independent test partition, with a generalization gap to 56.25% test accuracy attributed to dataset-acquisition heterogeneity and test partition size rather than a fundamental model failure. Both pipelines are integrated within a fully operational Flask web application that executes sub-second inference, applies confidence-threshold gating, and generates structured PDF screening reports. Planned future work addresses the three most significant limitations identified in this study. Dataset expansion is the highest priority: enlarging both the anemia-positive and normal-lens subsets, with images collected across multiple devices, lighting environments, and demographic groups, is prerequisite to generating reliable generalization estimates. Grad-CAM visualization will be integrated to confirm that model attention regions correspond to clinically meaningful anatomical structures. Model compression through quantization and pruning will be evaluated to support inference on mobile hardware. Finally, the evaluation framework will be upgraded to k-fold cross-validation and a minimum 200-image per-class held-out test set, enabling statistically defensible performance claims for subsequent submissions.
[1] P. Appiahene, Y. B. Missah, U. Danyuo, and E. K. Donkoh, “Detecting Anemia in Childhood Using Conjunctival Image Processing and Machine Learning Methods,” IEEE Access, vol. 10, pp. 45191–45205, 2022. [2] J. Lee, S. Kim, H. Park, and Y. Lee, “Deep learning-based non-invasive anemia detection from palpebral conjunctival images under ambient lighting conditions,” npj Digital Medicine, vol. 8, no. 1, pp. 1–10, 2025. [3] A. S. Razavian, H. Azizpour, J. Sullivan, and S. Carlsson, “CNN features off-the-shelf: An astounding baseline for recognition,” in Proc. IEEE CVPR Workshops, 2014, pp. 806–813. [4] S. Dhalla, S. Sheth, K. Shah, and J. Patel, “Conjunctival pallor detection using deep segmentation and classification networks for non-invasive anemia screening,” in Proc. IEEE EMBC, 2022, pp. 1894–1897. [5] V. Gulshan et al., “Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs,” JAMA, vol. 316, no. 22, pp. 2402–2410, 2016. [6] A. Esteva et al., “Dermatologist-level classification of skin cancer with deep neural networks,” Nature, vol. 542, pp. 115–118, 2017. [7] S. Devaraj, G. Raman, R. Shankar, and A. Kumar, “AI-based mobile cataract screening in rural India: Field deployment across 14 districts of Uttar Pradesh,” Lancet Digit. Health, vol. 5, no. 3, pp. e171–e179, 2023. [8] P. Appiahene, J. Ben Hayfron-Acquah, I. Asante, and T. Frempong, “Smartphone application for real-time non-invasive anemia detection using deep learning on conjunctival images,” Diagnostics, vol. 13, no. 15, Art. no. 2574, 2023. [9] M. Tan and Q. Le, “EfficientNet: Rethinking model scaling for convolutional neural networks,” in Proc. ICML, 2019, pp. 6105–6114. [10] A. Howard et al., “Searching for MobileNetV3,” in Proc. ICCV, 2019, pp. 1314–1324.
Publication Date
10/9/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
7
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...