Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM67759

Deep Learning Approaches for Simultaneous Cataract and Anemia Detection from Ocular Images Using EfficientNet-B0 and MobileNetV3-Small

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM67759

Volume:

10 |

10 |

Oct 2026

Pages:

1-5

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM67759

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

AK

Abhishek Kothawade

Computer Engineering

PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune

Download Author Certificate
SG

Sudhakar Gajare

Computer Engineering

PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune

Download Co-Author Certificate
SP

Shreyash Pachange

Computer Engineering

PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune

Download Co-Author Certificate

Mentors

PMK

Prof. Madhuri Kumbhar

Computer Engineering

PCCOER- Ravet, Pimpri Chinchwad College of Engineering and Research, Ravet, Pune

Download Mentor Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Timely mass screening for cataract and anemia is obstructed in low-resource settings by the cost and expertise demands of slit-lamp biomicroscopy and laboratory hemoglobin assays. This paper describes a dual-disease ocular screening system comprising two independent convolutional neural network pipelines integrated within a single Flask-based web application. Cataract detection employs EfficientNet-B0 fine-tuned on 4,081 eye images (1,066 normal, 3,015 cataract) with automatically computed inverse-frequency class weights and a two-phase training schedule: head-only optimization at a learning rate of 1×10⁻³ followed by selective backbone unfreezing at 1×10⁻⁶. Anemia screening employs MobileNetV3-Small trained on 988 conjunctival images (388 anemia-positive, 600 controls) with the final 30 backbone layers unfrozen, a fixed class weight of 1.5× on the minority class, and Adam optimization at 1×10⁻⁴. Both models are served at 224×224 pixel input resolution with runtime augmentation and confidence-threshold gating. On held-out test partitions, the anemia module achieved 87.50% accuracy with an AUC of 0.9023, and the cataract module achieved 83.46% validation accuracy with an AUC of 0.8992; the observed gap between validation and independent test performance for the cataract task is analyzed as a function of dataset size and acquisition heterogeneity. The deployed application supports PNG, JPG, and BMP input, executes inference in sub-second latency, and generates structured PDF screening reports, establishing a technically complete prototype for point-of-care ocular triage in resource-limited environments.

KEYWORDS

Cataract detection anemia screening EfficientNet-B0 MobileNetV3-Small transfer learning class imbalance two-phase fine-tuning Flask deployment point-of-care diagnostics conjunctival pallor analysis.

Cite This Article

Abhishek Kothawade, Sudhakar Gajare, Shreyash Pachange, Prof. Madhuri Kumbhar, "Deep Learning Approaches for Simultaneous Cataract and Anemia Detection from Ocular Images Using EfficientNet-B0 and MobileNetV3-Small," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 10, pp. 1-5, Oct 2026. https://doi.org/10.55041/IJSREM67759

Full Article/Conclusion

This paper presented the design, training, and deployment of a dual-pipeline ocular screening system pairing EfficientNet-B0 for cataract classification with MobileNetV3-Small for conjunctival anemia detection. The anemia module achieved 87.50% accuracy and an AUC of 0.9023 on a held-out test partition, with zero false positives recorded — a performance profile consistent with published single-disease anemia classifiers and sufficient to justify continued development toward clinical validation. The cataract module achieved 83.46% validation accuracy, an AUC of 0.8992, and a recall of 0.9768 on the independent test partition, with a generalization gap to 56.25% test accuracy attributed to dataset-acquisition heterogeneity and test partition size rather than a fundamental model failure. Both pipelines are integrated within a fully operational Flask web application that executes sub-second inference, applies confidence-threshold gating, and generates structured PDF screening reports. Planned future work addresses the three most significant limitations identified in this study. Dataset expansion is the highest priority: enlarging both the anemia-positive and normal-lens subsets, with images collected across multiple devices, lighting environments, and demographic groups, is prerequisite to generating reliable generalization estimates. Grad-CAM visualization will be integrated to confirm that model attention regions correspond to clinically meaningful anatomical structures. Model compression through quantization and pruning will be evaluated to support inference on mobile hardware. Finally, the evaluation framework will be upgraded to k-fold cross-validation and a minimum 200-image per-class held-out test set, enabling statistically defensible performance claims for subsequent submissions.

References

[1]     P. Appiahene, Y. B. Missah, U. Danyuo, and E. K. Donkoh, “Detecting Anemia in Childhood Using Conjunctival Image Processing and Machine Learning Methods,” IEEE Access, vol. 10, pp. 45191–45205, 2022. [2]  J. Lee, S. Kim, H. Park, and Y. Lee, “Deep learning-based non-invasive anemia detection from palpebral conjunctival images under ambient lighting conditions,” npj Digital Medicine, vol. 8, no. 1, pp. 1–10, 2025. [3]  A. S. Razavian, H. Azizpour, J. Sullivan, and S. Carlsson, “CNN features off-the-shelf: An astounding baseline for recognition,” in Proc. IEEE CVPR Workshops, 2014, pp. 806–813. [4]   S. Dhalla, S. Sheth, K. Shah, and J. Patel, “Conjunctival pallor detection using deep segmentation and classification networks for non-invasive anemia screening,” in Proc. IEEE EMBC, 2022, pp. 1894–1897. [5]   V. Gulshan et al., “Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs,” JAMA, vol. 316, no. 22, pp. 2402–2410, 2016. [6]  A. Esteva et al., “Dermatologist-level classification of skin cancer with deep neural networks,” Nature, vol. 542, pp. 115–118, 2017. [7]   S. Devaraj, G. Raman, R. Shankar, and A. Kumar, “AI-based mobile cataract screening in rural India: Field deployment across 14 districts of Uttar Pradesh,” Lancet Digit. Health, vol. 5, no. 3, pp. e171–e179, 2023. [8]   P. Appiahene, J. Ben Hayfron-Acquah, I. Asante, and T. Frempong, “Smartphone application for real-time non-invasive anemia detection using deep learning on conjunctival images,” Diagnostics, vol. 13, no. 15, Art. no. 2574, 2023. [9]     M. Tan and Q. Le, “EfficientNet: Rethinking model scaling for convolutional neural networks,” in Proc. ICML, 2019, pp. 6105–6114. [10]  A. Howard et al., “Searching for MobileNetV3,” in Proc. ICCV, 2019, pp. 1314–1324.

Editorial & Review Transparency

Publication Date

10/9/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

7

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...