Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM68675

Design and Evaluation of a Password-Based Switching Authorization System for Electric Lineman Safety

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM68675

Volume:

10 |

11 |

Nov 2026

Pages:

1-6

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM68675

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

B

B.Keerthi

Electronics And Communication Engineering

CMR Technical Campus

Download Author Certificate
B

B.Keerthi

Electronics and Communication

CMR Technical Campus

Download Co-Author Certificate
T

T.Abhisharan

Electronics and Communication

CMR Technical Campus

Download Co-Author Certificate
BG

B.Ganesh Goud

Electronics and Communication

CMR Technical Campus

Download Co-Author Certificate
PN

P.Saidhiah Naidu

Electronics and Communication

CMR Technical Campus

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Maintenance on de-energized distribution lines is endangered by unintended re-energization, a hazard that conventional verbal switching coordination cannot exclude. This paper presents the design of a password-based switching authorization system in which an Arduino-based controller accepts a password from a matrix keypad, validates it, and, only on a valid entry, signals a relay interface that switches a low-voltage demonstration load; an LCD and a buzzer provide status and alerts. We specify the architecture, a state model of the controller, a proposed authentication and switching algorithm, and a reproducible test protocol with acceptance criteria. A safety analysis identifies password compromise, tampering, relay and controller faults, and power loss as the dominant residual risks, and argues that automatic relay closing after maintenance is hazardous and should be replaced by deliberate authorization combined with independent confirmation that work is complete. No experimental measurements are yet available, so no performance claims are made. The system is positioned as an additional authorization measure, not a substitute for electrical isolation, lockout/tagout and verification of de-energization.

KEYWORDS

Authorization circuit breaker electrical maintenance safety embedded systems lineman safety password authentication relay control.

Cite This Article

B.Keerthi, B.Keerthi, T.Abhisharan, B.Ganesh Goud, P.Saidhiah Naidu, "Design and Evaluation of a Password-Based Switching Authorization System for Electric Lineman Safety," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 11, pp. 1-6, Nov 2026. https://doi.org/10.55041/IJSREM68675

Full Article/Conclusion

This paper specified the architecture, controller states, a proposed algorithm and an evaluation protocol for an Arduino-based password-authorized switching system for lineman safety, and analysed its residual risks. The basic concept is established in earlier work; the contribution lies in the explicit state model and safe-behaviour requirements, the rejection of automatic re-closing in favour of deliberate authorization with confirmation, and a reproducible low-voltage test plan. Because no measurements are available, no claim of effectiveness is made, and the system does not guarantee lineman safety. It should be used only as an additional measure alongside isolation, lockout/tagout and verification of de-energization. Future work, none of which is implemented, includes completing the evaluation of Section VII; adding attempt limiting and per-user or one-time credentials; logging of attempts and operations; independent state feedback from the load side; a hardware interlock that does not depend on the microcontroller; a defined fail-safe relay default and backup supply; and, if remote features are added, a security analysis of the communication path.

References

[1] M. G. Hudedmani, N. Ummannanavar, M. D. Mudaliar, C. Sooji, and M. Bogar, “Password based distribution panel and circuit breaker operation for the safety of lineman during maintenance work,” Adv. J. Grad. Res., vol. 1, no. 1, pp. 35–39, Feb. 2017. [Online].                                       Available:https://journals.aijr.org/index.php/ajgr/article/view/160 [2]  S. A. Soomro et al., “Design of IoT based protection system for distribution breakers using Arduino,” QUEST Res. J., Dec. 2021,   doi:   10.52584/QRJ.1902.05.       [Online]. Available: https://publications.quest.edu.pk/ojs/index.php/qrj/article/view/1 94 (volume and pages [TBC]) [3]  R. G. Shriwastava, P. C. Tapre, R. M. Rewatkar, and S. M. Choudhary, “Hardware implementation of safety smart password based GSM module controlling circuit breaker,” Int. J. Appl. Power Eng., accepted Jan. 2025. [Online]. Available: https://ijape.iaescore.com/index.php/IJAPE/article/download/21 538/13325 (volume, pages and DOI [TBC]) [4] A. N. S. Mohamed, A. A. A. Ahmed, M. K. I. Mohamed, and M. M. E. Jala Aldeen, “Password based circuit breaker using Arduino Uno,” B.Sc. thesis, Coll. Eng., Sudan Univ. Sci. Technol., Khartoum, Sudan, 2020. [Online]. Available: http://repository.sustech.edu/handle/123456789/26413 [5] J. Veena, G. Srivani, Afreen, M. Sunil Kumar, J. Santhosh, and K.B. V. S. R. Subrahmanyam, “Electric lineman protection using user changeable password based circuit breaker,” Int. J. Curr. Eng. Sci. Res., vol. 2, no. 5, pp. 44–49, 2015. (Verified only ascited in [1].) [6]  P. N. Mahadik, P. A. Yadav, S. B. Gotpagar, and H. P. Pawar, “Electric line man safety using micro controller with GSM module,” Int. J. Sci. Res. Dev., vol. 4, no. 1, pp. 205–207, 2016. (Verified only as cited in [1].) [7]    “Keypad/Bluetooth/GSM based digital door lock security system,” in Proc. Int. Conf. Commun. Signal Process. (ICCASP 2016), Atlantis Press, Dec. 2016, pp. 726–734, doi: 10.2991/iccasp-16.2017.102. (Author list [TBC] from the DOI record.) [8]  Occupational Safety and Health Administration, “The control of hazardous energy (lockout/tagout),” 29 CFR 1910.147. [Online]. Available:         https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 [9]   Occupational Safety and Health Administration, “Control of hazardous energy (lockout/tagout),” overview page (refers to 29 CFR 1910.269 for power generation, transmission and distribution).                                [Online].   Available: https://osha.gov/SLTC/controlhazardousenergy/index.html [10]     Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems – Part 1: General Requirements, IEC 61508-1:2010, Apr. 2010.

Editorial & Review Transparency

Publication Date

11/2/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

6

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.