Students of refrigeration and air conditioning rarely get to watch a vapour-compression cycle at work, because commercial window units hide every component behind a sealed casing. This paper describes the design of a compact, open-frame window air-conditioner setup built to remedy that for HVAC teaching and laboratory demonstration. The proposed unit contains a hermetic compressor, an air-cooled condenser, an expansion device, an evaporator, an indoor blower, a condenser fan, copper piping, an electrical panel and planned instrumentation, all arranged so that each part can be seen, reached and measured. The arrangement was developed through a literature survey, component selection, three-dimensional CAD modelling and a pre-fabrication review of layout, clearances and expected operating sequence. Temperature, pressure and airflow measurement points are fixed in the design, and space is kept for a later data-acquisition system. A steady-state energy-balance model is presented for computing cooling capacity, compressor work, heat rejection and coefficient of performance once the unit is tested. No measured data or solved state-point values exist at this stage, so the paper makes no numerical performance claims. It offers a reviewed design basis for fabrication, experimental validation and later work on digital monitoring.
KEYWORDS
A compact window air-conditioner setup based on the vapour-compression cycle has been designed and reviewed as a platform for HVAC teaching. Its open layout keeps the compressor, condenser, expansion device, evaporator, fans, piping and instrument points visible and accessible, and CAD modelling allowed placement, clearances and safety to be examined before anything is built. The main contribution at this stage is a design framework and an evaluation method that treat visibility, access and measurability as design goals. Because no measured data or solved state-point values exist, the paper reports no cooling-capacity or COP figures, and those will have to come from the fabricated and tested unit. The setup is intended for laboratory demonstration and experiment and gives a base for fabrication, data acquisition and further study.
[1] Ismail, A.; Mahusin, M.B.; Asary, L.H.; Zubir, Z.; Masek, A.; Dardiri, D.A. Developing a smart window air conditioner training kit for vocational students: An effective teaching kit. Univers. J. Educ. Res. 2020, 8, 4303–4312. doi: 10.13189/ujer.2020.080957. [2] Ryan, R.G. Design of a portable experiment for demonstrating air conditioning processes. In Proceedings of the 2001 ASEE Annual Conference & Exposition, 2001. [3] Amran, A.Z.; Latiff, Z.A.; Nasution, H.; Perang, M.R.M.; Jamil, H.M.; Misseri, M.N. Development and evaluation of an automotive air-conditioning test rig. Jurnal Teknologi 2016, 78, 55–60. [4] Chaiyat, N. Energy and economic analysis of a building air-conditioner with a phase change material (PCM). Energy Convers. Manag. 2015, 94, 150–158. doi: 10.1016/j.enconman.2015.01.068. [5] Luo, B.; Li, F.; Wu, S.; Shi, K.; Ding, Y.; Zhao, R.; Huang, D.; Shi, W. Experimental and numerical research on a C-type heat exchanger in duct air conditioner under non-uniform airflow. Appl. Therm. Eng. 2025, 261, 125097. doi: 10.1016/j.applthermaleng.2024.125097. [6] Elsaid, A.M.; Shamsia, I.; Fatouh, M.; Ahmed, M.S. Novel design of a vapor compression air conditioning system incorporated with an indirect evaporative cooler under various configurations for enhanced energy efficiency. Int. Commun. Heat Mass Transf. 2026, 177, 111485. doi: 10.1016/j.icheatmasstransfer.2026.111485. [7] Kang, H.; Heo, J.; Kim, Y. Performance characteristics of a vapor compression cooling cycle adopting a closed-loop air-circulation system for avionic reconnaissance equipment. Int. J. Refrig. 2012, 35, 785–794. [8] Mota-Babiloni, A.; Navarro-Esbrí, J.; Barragán-Cervera, Á.; Molés, F.; Peris, B. Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapour compression system as R134a replacements. Appl. Therm. Eng. 2014, 71, 259–265. [9] Sánchez, D.; Cabello, R.; Llopis, R.; Arauzo, I.; Catalán-Gil, J.; Torrella, E. Energy performance evaluation of R1234yf, R1234ze(E), R600a, R290 and R152a as low-GWP R134a alternatives. Int. J. Refrig. 2017, 74, 267–280. [10] Dağıdır, K.; Bilen, K. Usage of R513A as an alternative to R134a in a refrigeration system: An experimental investigation based on the Kigali amendment. Int. J. Thermofluids 2024, 21, 100582
Publication Date
10/26/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
1
Total views since publication
PDF Downloads
5
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
Funding Agency: ASHRAE
Grant / Project ID: Equipment Grant
Related research in the same subject area
Loading similar articles...