Stream/Area:
-
Subject:
-
Paper ID:
IJSREM65794
Volume:
10 |
7 |
Jul 2026
Pages:
1-9
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Department of civil engineering
Karpagam academy of higher education

Department of civil engineering
Karpagam academy of higher education
The way waste foundry sand is disposed of in industry presents serious environmental problems. particularly in the foundry sector, To address this issue, an experimental investigation was conducted and evaluate the effects on Using leftover foundry sand in concrete to partially substitute natural sand, specifically targeting M30 grade concrete, which design is to achieve compressive strength of 30 MPa in 28 days. In the study, percentage (0%,25%,50%,100%) of the foundry sand was replaced with fine aggregate. The performance in both conventional concrete and concrete with WFS was assessed through various tests, including compressive strength, using the weight loss method in cement mortar (CM).The results revealed a slight improvement in strength and durability. Notably, the benefits were more pronounced in MM 10 grade cement mortar. This research highlights the potential of utilizing industrial by-products like WFS in construction, contributing to waste reduction and promoting sustainable practices in the concrete industry.
KEYWORDS
l The present study examined the physical and chemical characteristics of waste foundry sand (WFS). The compressive strength of concrete was evaluated using both untreated and reclaimed WFS as partial replacements for natural sand at proportions of 25%, 50%, 75%, and 100%. Based on the experimental findings, the following conclusions were drawn. l From the tests conducted on the six concrete mixtures, it was observed that at all curing ages, the strength of concrete containing up to 25% WFS and reclaimed WFS was nearly comparable to that of the conventional mix (CM). However, mixtures with 25% to 50% replacement levels showed a slight reduction in compressive strength. At 28 days, the decrease was approximately 1.6% and 5.7%, respectively, compared to the conventional mix. l It shows the 25% and 50% of Partial replacement of foundry sand concrete is best one compare to cc. l The results indicate that waste foundry sand (WFS) and reclaimed WFS can be effectively used as partial replacements for fine aggregate up to 25% and 50%. At these replacement levels, good quality concrete can be produced without compromising the required standards.
[1] IS 10262–2009: Indian Standard “Guidelines for concrete mix design proportioning” – code of practice. [2] IS 456 – 2000: Indian Standard “Plain and reinforced concrete” – code of practice. [3] IS 383 – 1970 : Indian Standard “Specification for coarse and fine aggregates from naturals sources for concrete” [4] IS: 2386(Part I)-1963. “methods of test for aggregates for concrete” [5] J. Jeyanthi et.al (2023), “Study of concrete with partial replacement of waste foundry sand for fine aggregate and granite waste for coarse aggregate” [6] Wenzhong Zheng et.al (2023), “Preparation of ultra-high performance concrete containing waste foundry sand and its application in structures” [7] M.Arun et.al(2021), “Cost effective construction materials for economically weaker section” [8] V. Brindha Devi et.al. (2023), “Experimental investigation on utilization of used foundry sand in concrete as fine aggregate” [9] P.PendhariAnush et.al. (2017), “Partial replacement of sand by waste foundry sand”. Journal of Civil Engineering Research ( JCER ). [10] Saifali et.al. (2017), “A Review of Utilization of Waste foundry sand” Journal of Civil Engineering Research ( JCER ).
Publication Date
7/3/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
0
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...