This study examines the influence of basic wind speed on the structural response and preliminary member-selection requirements of a single-storey industrial steel portal-frame building. The building has a plan dimension of 30 m × 20 m, an eave height of 8 m, a ridge height of 10 m and six bays at 5 m spacing. Four wind-speed cases—33, 39, 47 and 55 m/s—are compared while the geometry and nominal non-wind loading assumptions remain unchanged. Wind pressure is estimated using p = 0.6V², with the simplifying assumption Vz = Vb. The illustrative values show an increase in pressure from 0.653 to 1.815 kN/m², maximum lateral displacement from 18.0 to 50.0 mm, maximum column moment from 185 to 512 kN·m, base shear from 110 to 306 kN and uplift reaction from 42 to 117 kN. The assumed steel quantity increases from 23.5 to 32.0 tonnes. The 55 m/s case produces the highest illustrative demand, with a maximum member utilization ratio of 0.93. The structural response values are assumed for academic parametric evaluation and are not actual STAAD.Pro analysis outputs. Accordingly, the results provide an illustrative comparative framework rather than a validated numerical analysis. A complete STAAD.Pro model, code-compliant wind-load derivation and independently checked member design are required before the findings can support engineering decisions.
KEYWORDS
· The simplified pressure values increase from 0.653 kN/m² at 33 m/s to 1.815 kN/m² at 55 m/s, an increase of approximately 177.8%, reflecting the square-law relationship between velocity and pressure. · In the illustrative dataset, maximum lateral displacement increases from 18.0 to 50.0 mm and maximum vertical displacement from 8.5 to 23.6 mm. · The assumed maximum column and rafter moments increase from 185 to 512 kN·m and 162 to 449 kN·m, respectively; maximum axial force rises from 145 to 403 kN. · The assumed base shear increases from 110 to 306 kN and uplift reaction from 42 to 117 kN, indicating the importance of foundation shear and uplift resistance in high-wind conditions. · The assumed maximum utilization ratio rises from 0.62 to 0.93. The illustrative member schedule changes from ISMB 400 columns/ISMB 350 rafters at 33 m/s to ISMB 450 columns/ISMB 450 rafters at 55 m/s. · The assumed steel quantity increases from 23.5 to 32.0 tonnes, corresponding to approximately 36.2%. · The 55 m/s case is the governing case within the illustrative dataset. However, none of the assumed response values should be treated as validated STAAD.Pro output until the complete model and code checks are provided.
[1] Bureau of Indian Standards, IS 875 (Part 1), Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures—Dead Loads, New Delhi, India. [2] Bureau of Indian Standards, IS 875 (Part 2), Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures—Imposed Loads, New Delhi, India. [3] Bureau of Indian Standards, IS 875 (Part 3):2015, Design Loads (Other than Earthquake) for Buildings and Structures—Wind Loads, New Delhi, India, 2015. [4] Bureau of Indian Standards, IS 800:2007, General Construction in Steel—Code of Practice, New Delhi, India, 2007. [5] Bureau of Indian Standards, IS 801, Code of Practice for Use of Cold-Formed Light Gauge Steel Structural Members in General Building Construction, New Delhi, India. [6] Bureau of Indian Standards, IS 1893 (Part 1), Criteria for Earthquake Resistant Design of Structures, New Delhi, India. [7] Bentley Systems, STAAD.Pro CONNECT Edition: Structural Analysis and Design Software Documentation, Bentley Systems, Inc. [8] G. S. Kiran, A. K. Rao, and R. P. Kumar, “Comparison of Design Procedures for Pre-Engineered Buildings: A Case Study,” International Journal of Engineering Research and Technology, 2015. [9] N. R. Kolate and S. Kewate, “Comparative Study of Pre-Engineered and Conventional Steel Frames for Different Wind Zones,” International Journal of Engineering Research and Technology, 2015. [10] P. S. Lande and V. V. Kucheriya, “Comparative Study of an Industrial Pre-Engineered Building with Conventional Steel Building,” International Journal of Engineering Research and Technology, 2015.
Publication Date
11/13/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...