Corrugated plate heat exchangers (CPHEs) possess a greater surface area for heat transfer and a heightened level of turbulence as a result of the corrugations. This study presents an experimental analysis comparing the thermal performance of a flat plate heat exchanger and a corrugated plate heat exchanger (CPHE) with varied corrugation angles. The analysis was conducted using water as the test fluid. The comprehensive testing has been carried out on CPHEs with different chevron angles (β) of 30°/30°, 45°/45°, and 60°/60°. Experimental data is collected under steady-state conditions, with a single phase (water-water) system, covering Reynolds numbers (Re) ranging from 900 to 1250. The test fluid’s mass flow rate, ranging from 0.05 to 0.16 kilograms per second, is measured together with the accompanying steady state temperatures. Each plate was equipped with four thermocouple sensors to detect the bulk temperature of the cold and hot fluids at the intake and output. The performance was evaluated using both parallel and counterflow configurations. Experimental observations are utilized to estimate the temperature difference (∆T) between the inlet and output streams, the logarithmic mean temperature difference (LMTD), and the exergy (E). The measured ∆T and E values for corrugation angles (30°, 45°, and 60°) of CPHE were compared to those of flat plate heat exchangers. For corrugation angles of 30°, 45°, and 60°, the values of ∆T and E (efficiency) increase as the mass flow rate of the fluid increases. An increase in the corrugation angle leads to an increase in turbulence in the flow, which in turn enhances heat transmission. In addition, the thermal effectiveness (ε) was calculated using the NTU method and compared for all of the plates.
KEYWORDS
Publication Date
7/30/2024
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
5
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...