Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
10.55041/IJSREM17682
Volume:
7 |
2 |
Feb 2023
Pages:
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
In recent days in distribution system the more importance is giving to Loss minimization techniques since electricity demand is continuously increasing and utility companies are struggling to meet this rapid increase in load due constraints on energy resource to increase the generation. Furthermore, voltage instability phenomena is also playing important role in distribution systems and caused a major blackout in the network. To solve the above problem new technology that is drawing more attention is Distributed Generation (DG). Placing DG in the distribution system inherently reduces the power loss and improves the system voltage. The selection of type of DG, proper placement and sizing of DG plays an important role. This paper presents an effective methodology to identify the optimum location of multi type DG in the distribution system in order to reduce the losses and improve the voltage. In this work the IEEE 33-Bus system is simulated in Power World Simulator (PWS) and the voltage stability and system losses are analyzed with different types of DGs and combination of different types of DGs are studied. Simulation result shows that optimal placement and sizing of DG will reduce the system losses and improve the voltage profile within the acceptable limits and the loss reduction and voltage profile improvement are depending on the types of DGs and combination of DGs placed in the distribution system.
KEYWORDS
Publication Date
5/1/2023
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
1
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...