This paper presents a source-based study of unified power quality conditioner (UPQC) control for an oscillating-water-column wave-energy converter coupled to a permanent-magnet synchronous generator (PMSG). The architecture uses series and shunt voltage-source converters sharing a DC link. Frequency-fixed second-order generalized integrator (FFSOGI) quasi-type-1 phase-locked loops (QT1-PLLs) support phase estimation and sequence extraction; nonlinear proportional–integral (N-PI) control with feedforward supports DC-link regulation. The supplied documentation reports PSCAD/EMTDC comparisons for unbalanced nonlinear loads and voltage faults, including approximately 14 ms DC-link startup with the proposed control versus more than 40 ms for a conventional controller, and approximately 1.8% source-current THD under a reported disturbance case. Figures reproduced here originate from the supplied project document; no independent simulation or experimental verification has been performed.
KEYWORDS
The supplied project evidence supports the usefulness of coordinated series and shunt UPQC control in a wave-energy-driven PMSG architecture. FFSOGI-QT1-PLL synchronization, positive-sequence extraction and nonlinear DC-link regulation are the central reported design features. Documented simulations show improved voltage disturbance mitigation, source-current quality and DC-link transient response compared with conventional control. These are source-reported outcomes and require model-level replication before being represented as new independent experimental findings.
[1] Bhavani, “Improved UPQC Control System for Wave Energy-Powered PMSG System Power Quality Enhancement,” project documentation supplied by the author, undated. [2] H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous Power Theory and Applications to Power Conditioning, 2nd ed. Hoboken, NJ, USA: Wiley-IEEE Press, 2017. [3] A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices. Boston, MA, USA: Kluwer Academic, 2002. [4] V. Khadkikar, “Enhancing electric power quality using UPQC: A comprehensive overview,” IEEE Trans. Power Electron., vol. 27, no. 5, pp. 2284–2297, May 2012. [5] H. Fujita and H. Akagi, “The unified power quality conditioner: The integration of series- and shunt-active filters,” IEEE Trans. Power Electron., vol. 13, no. 2, pp. 315–322, Mar. 1998. [6] P. Rodríguez et al., “Grid synchronization of power converters using multiple second order generalized integrators,” in Proc. 34th Annu. Conf. IEEE Ind. Electron. Soc. (IECON), 2008, pp. 755–760. [7] F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid synchronization for distributed power generation systems,” IEEE Trans. Ind. Electron., vol. 53, no. 5, pp. 1398–1409, Oct. 2006. [8] IEEE Std 519-2022, IEEE Standard for Harmonic Control in Electric Power Systems. IEEE, 2022. [9] J. Falnes, Ocean Waves and Oscillating Systems: Linear Interactions Including Wave-Energy Extraction. Cambridge, U.K.: Cambridge Univ. Press, 2002. [10] A. F. de O. Falcão, “Wave energy utilization: A review of the technologies,” Renew. Sustain. Energy Rev., vol. 14, no. 3, pp. 899–918, 2010.
Publication Date
10/30/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
4
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...