Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM15368
Volume:
6 |
7 |
Jul 2022
Pages:
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
This experimental investigation exemplifies the design and testing of four diffusers at compressor inlet and condenser inlet in the vapour compression refrigeration system with the help of R134a refrigerant .The Four diffusers with divergence angle of 10°,12°, 14° are designed for same inlet and outlet diameters. Diffusers are testing at compressor inlet first. The diffusers are used with inlet diameter equal to discharging tube diameter of evaporator and outlet diameter is equal to suction tube diameter of the compressor. One of the diffuser gives the better performance, it will fixed at compressor inlet. Then diffusers are testing at condenser inlet, diffuser inlet diameter equal to discharging tube diameter of compressor and outlet diameter equal to condenser inlet diameter The system is analyzes using the first and second laws of thermodynamics, to determine the refrigerating effect, the compressor work input, coefficient of performance(COP). During the experimental test,the coefficient of performance (COP) of the system without diffuser and with diffuser optimized at compressor inlet and condenser inlet are find out. At compressor inlet 14° divergence angle of diffuser given the maximum cop (2.46). Percentage of increase in cop is approximately 6%. At condenser inlet 12° divergence angle of diffuser given the maximum cop (2.59).Percentage of increase in cop is approximately 3%.
KEYWORDS
Publication Date
7/6/2022
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
1
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...