Low-voltage microgrids incorporating photovoltaic (PV) generation face intermittent power injection, nonlinear-load harmonics, voltage disturbances and converter overcurrent. This paper consolidates a coordinated photovoltaic–battery energy storage system (BESS)–unified power quality conditioner (UPQC) architecture for simultaneous energy management and power-quality compensation. A series converter regulates the load-side voltage, while a shunt converter suppresses current harmonics, supplies reactive current and controls the common DC link. A bidirectional battery converter uses a state-of-charge-aware dynamic power reference, and adaptive current-sharing factors protect the shunt converter during excessive load transients. Results reported in the source documentation include a reduction of grid-current total harmonic distortion from a 27.61% nonlinear-load current to 2.47% in a normal operating case, while protection mode permits a temporary 7.70% grid-current THD to avoid overloading the converter. The paper examines system design, controller logic, representative waveforms, operating constraints and validation limitations.
KEYWORDS
The presented figures are reproduced from the uploaded documentation, not generated by a new simulation run. Numerical conclusions are therefore limited to the cases, parameterization and measurements reported in that source. The major technical contribution is coordinated operation of PV, battery and UPQC using one common DC link, alongside reference-current-based switch protection. This arrangement can reduce grid burden, mitigate harmonic currents and maintain load voltage during sag events. However, the trade-off between temporary grid-current distortion and switch protection needs explicit evaluation against grid-code limits. Reproducibility also requires complete component ratings, switching frequency, sample time, plant parameters and original MATLAB/Simulink files, which are not supplied as executable models in the uploaded document. In conclusion, the documented PV–BESS–UPQC strategy provides a useful architecture for power-quality improvement and DER management in low-voltage microgrids. Reported tests demonstrate substantial normal-mode harmonic reduction and rapid protective current redistribution during overload. Further work should compare baseline and proposed controls under identical parameter sets, quantify losses and energy efficiency, and independently validate robustness over a wider range of battery SOC and grid disturbances.
[1] P. Ray, M. L. K. Liyanage, P. K. Ray, and P. S. Puhan, “Grid following and grid forming control modes of der fed vsi with transition of operational modes for microgrid with critical load,” in 2023 5th International Conference on Energy, Power and Environment: Towards Flexible Green Energy Technologies (ICEPE), 2023, pp. 1–6. [2] V. Khadkikar, “Enhancing electric power quality using upqc: A comprehensive overview,” IEEE Transactions on Power Electronics, vol. 27, no. 5, pp. 2284–2297, 2012. [3] A. Heenkenda, A. Elsanabary, M. Seyedmahmoudian, S. Mekhilef, A. Stojcevski, and N. F. A. Aziz, “Unified power quality conditioners based different structural arrangements: A comprehensive review,” IEEE Access, vol. 11, pp. 43 435–43 457, 2023. [4] L. B. G. Campanhol, S. A. O. da Silva, A. A. de Oliveira, and V. D. Bacon, “Single-stage three-phase grid-tied pv system with universal filtering capability applied to dg systems and ac microgrids,” IEEE Transactions on Power Electronics, vol. 32, no. 12, pp. 9131–9142, 2017. [5] D. Sera, L. Mathe, T. Kerekes, S. V. Spataru, and R. Teodorescu, “On the perturb-and-observe and incremental conductance mppt methods for pv systems,” IEEE Journal of Photovoltaics, vol. 3, no. 3, pp. 1070–1078, 2013. [6] N. Femia, G. Petrone, G. Spagnuolo, and M. Vitelli, “Optimization of perturb and observe maximum power point tracking method,” IEEE Transactions on Power Electronics, vol. 20, no. 4, pp. 963–973, 2005. [7] V. Monteiro, C. Moreira, J. A. Pecas Lopes, C. H. Antunes, G. J. Os´orio, J. P. S. Catal˜ao, and J. L. Afonso, “A novel three-phase multiobjective unified power quality conditioner,” IEEE Transactions on Industrial Electronics, vol. 71, no. 1, pp. 59–70, 2024. [8] S. Devassy and B. Singh, “Performance analysis of solar pv array and battery integrated unified power quality conditioner for microgrid systems,” IEEE Transactions on Industrial Electronics, vol. 68, no. 5, pp. 4027–4035, 2021.
Publication Date
10/30/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
4
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...