Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM69166
Volume:
10 |
11 |
Nov 2026
Pages:
1-11
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Civil Engineering
Deogiri Institute of Engineering and Department, Chh. Sambhajinagar, Maharashtra
Civil Engineering
Deogiri Institute of Engineering and Department, Chh. Sambhajinagar, Maharashtra
Civil Engineering
Deogiri Institute of Engineering and Department, Chh. Sambhajinagar, Maharashtra
Civil Engineering
Deogiri Institute of Engineering and Department, Chh. Sambhajinagar, Maharashtra
Civil Engineering
Deogiri Institute of Engineering and Department, Chh. Sambhajinagar, Maharashtra
The demand for high-density urban development has led to structural configurations in which two or more towers are linked by horizontal connecting elements known as sky walks or sky bridges. While such links offer architectural and functional advantages by providing shared circulation and amenity space between towers, they fundamentally alter the dynamic behaviour of the combined structural system. The connected towers no longer respond as independent structures; the sky walk attracts a share of lateral demand that a conventional isolated-tower analysis would never reveal, and the link itself becomes a critical structural element. This paper presents the analysis and design of a G+20 reinforced concrete twin-tower building in which the two towers are connected by a sky walk of 8 m × 28 m plan dimension provided at every floor level. The structure is analysed for dead load, live load, wind load and seismic load using STAAD.Pro 2026. The seismic analysis is carried out for Seismic Zone III with an importance factor corresponding to a high-importance functional category, on medium stiff soil. The lateral-force-resisting system consists of a reinforced concrete moment-resisting frame, without shear walls or bracing. Wind load is evaluated as a static equivalent pressure in accordance with IS 875 (Part 3):2015, and earthquake effects are evaluated using both the equivalent static method and response spectrum analysis as per IS 1893 (Part 1):2016. Member design is carried out directly from the analysis results using the IS 456:2000 design codes embedded in the software. Analysis results establish that the sky-walk connection acts as a stiffening and coupling element between the two towers, forcing them to deform together rather than independently, and that the sky-walk beams develop significant axial force under reversed lateral loading, requiring design for combined axial and flexural action. The study demonstrates that a single integrated three-dimensional model in STAAD.Pro 2026 provides a practical and efficient workflow for this class of geometrically complex structure, and concludes that the multi-level sky walk must be treated as a primary structural system rather than a secondary architectural element.
KEYWORDS
1. A G+20 reinforced concrete twin-tower structure with an 8 m × 28 m sky walk provided at every floor level was successfully modelled, analysed and designed within a single three-dimensional model in STAAD.Pro 2026, using a purely frame-based lateral-force-resisting system without shear walls or bracing. 2. The sky-walk connection acts as a stiffening and coupling element between the two towers. Each tower is restrained by the lateral stiffness of the other, and the combined system resists lateral load through a mechanism that does not rely on shear walls. 3. At every floor level the sky-walk slab and its perimeter frame act as a deep horizontal truss, transferring storey shear between the two towers. Because this action occurs at all 21 levels rather than at a small number of service levels, the coupling is distributed over the full height of the structure. 4. The sky-walk beams develop axial force of reversing sign under reversed lateral loading, as demonstrated by the extracted member forces in which the longitudinal force changes from −6.896 kN under EQ+X to +6.896 kN under EQ−X. The axial force is constant along the member length, indicating truss-chord rather than flexural behaviour. Sky-walk members must therefore be designed for combined axial and flexural action. 5. The columns immediately adjacent to the sky walk experience a short-column effect caused by the restraint of the link slab at every floor, and require enhanced shear reinforcement over the affected height. 6. Earthquake loading governs the design of the sky-walk members for the site and configuration considered. Wind-induced member forces were an order of magnitude smaller than the corresponding seismic forces. 7. The re-entrant, cruciform plan of each tower renders the structure torsionally irregular within the meaning of the IS 1893 criteria, 8. making the accidental eccentricity provision a governing consideration and making the torsional response of the towers relative to one another a direct influence on the sky-walk demand. 9. STAAD.Pro 2026 provides an efficient single-platform workflow for this class of structure, allowing geometry definition, load generation, response spectrum analysis, member design and ductile detailing checks to be carried out within one model, which is essential where the connecting elements cannot be assigned to either tower individually. 10. The overall conclusion is that a multi-level sky-walk scheme is structurally viable using a frame system alone, but demands that the link be treated as a primary structural system rather than as an architectural addition.
1. IS 1893 (Part 1):2016, Criteria for Earthquake Resistant Design of Structures — Part 1: General Provisions and Buildings, Bureau of Indian Standards, New Delhi. 2. Bhushan Katkar and Mr. S. B. Deshmukh (2026) Evaluating the Impact of Wind Load on Tall Irregular Structures- A Review. International Journal of Engineering Development and Research (2321-9939), 14 (2), 817-823 www.ijedr.org. 3. Aniket Manoj Jadhav and Prof. Sandip Deshmukh (November-December- 2025) Non-Linear Analysis of Cable Strayed Bridge Using Staad-Pro. International Journal of Engineering Research and Management Technology (ISSN: 2348-4039),12(6),46-51. doi.org/10.34291/ijermt 12.6/547323 4. Manasi S. Palsikar, Prof. S. B. Deshmukh (September 2023) Non-Linear Dynamic Analysis of Cable Stayed Bridge with Different Cable Arrangements, International Advanced Research Journal in Science, Engineering and Technology (ISSN (O) 2393-8021, ISSN (P) 2394-1588). DOI:10.17148/IARJSET.2023.10930. https://iarjset.com/wp-content/uploads/2023/10/IARJSET.2023.10930.pdf 5. Shaikh Mohd Abdul Gaffar Mohd Abdul Waheeda, Prof. S.B Deshmukh (September/2023) Comprehensive Analysis of Aerodynamic Modifications: Evaluating Wind-Induced Performance in G+15 Buildings with Varied Corner Configurations, Journal of Applied Science and Computations, ( ISSN NO: 1076-5131) 10(9), pg no44-54 6. Shaikh Mohd Abdul Gaffar Mohd Abdul Waheed , Prof. S.B Deshmukh. (October-2023) Literature Review on Wind induced performance analysis of Aerodynamic Modified Buildings with varied corners", TIJER - TIJER - INTERNATIONAL RESEARCH JOURNAL (www.TIJER.org), ISSN:2349-9249, Vol.10, Issue 10, page no.a114-a119, , https://tijer.org/TIJER/papers/TIJER2310013.pdf 7. Sanket Kiranrao Doke, S.B. Deshmukh. (2023)Comparative Study of RC Elevated Water Tank, Journal of Structural Engineering and Management · Vol. 10, Issue 3, 2023 · pp. 12–19, DOI (Journal): 10.37591/JoSEM 8. Sanket S. Kale, Sandip B. Deshmukh, DR. G. R. Gandhe (August 2022), Seismic Analysis of RC Building on Different Soil Types Considering Soil Interaction, International Journal of Advances in Engineering and Management (IJAEM) Volume 4, Issue 8, Page No : 1758-1764 DOI : 10.35629/5252-040817581764 9. Sanket S. Kale, Sandip B. Deshmukh, DR. G. R. Gandhe (2022), Seismic Response of RC Frame Considering Soil Structure Interaction By Varying Soil Type – A Review, Journal of Applied Science and Computations 10(8), ISSN NO: 1076-5131Page 10. Nikhil A Lokhande, Prof. D. S. Wadje, Prof. S. B. Deshmukh, Dr. G. R. Gandhe(Dec 2017), Seismic Analysis & Design of Ductile Detailed Reinforced Concrete Structure with reference to IS13920:1993(Old Code) & IS13920:2016 (Revised Code), International Journal of Recent Research Aspects IJRRA ISSN: 2349-7688,page 373-379 https://www.ijrra.net/Vol4issue4/IJRRA-04-04-86.pdf
Publication Date
11/18/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
1
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...