The present study experimentally investigates the use of recycled coarse aggregate (RCA) recovered from construction and demolition (C&D) concrete waste in M20, M30 and M40 concrete. Natural coarse aggregate was replaced by RCA at 0%, 10%, 20%, 30%, 40%, 50% and 100%. The study further examined the effect of replacing cement with silica fume at 5%, 10% and 15% in mixes containing the selected 30% RCA, followed by the incorporation of crimped steel fibres. Fresh concrete workability, 7-, 28- and 90-day compressive, split tensile and flexural strengths, chemical exposure response, water absorption, microstructural observations and reinforced-concrete beam behaviour were considered. The tabulated results identify 30% RCA as the best-performing replacement level among the investigated RCA-only mixtures. At 28 days, the 30% RCA mixes reached compressive strengths of 26.0, 37.5 and 47.76 MPa for M20, M30 and M40, respectively, compared with 23.80, 34.85 and 43.90 MPa for the corresponding controls. Incorporating 15% silica fume increased these values to 35, 51.5 and 58 MPa. For the M40 beam series, the ultimate load increased from 75 kN for the control to 95 kN for the mix containing 30% RCA, 15% silica fume and 1.5% steel fibre. The results indicate potential benefits from combining processed RCA, silica fume and steel fibres; however, inconsistencies in fibre dosage, beam counts, loading description, durability reporting and some conclusions require verification before design-level interpretation.
KEYWORDS
• Among the tested RCA-only mixtures, 30% replacement of natural coarse aggregate gave the highest reported 28-day compressive, split tensile and flexural strengths for M20, M30 and M40 concrete. • At 30% RCA, 28-day compressive strengths were 26.0, 37.5 and 47.76 MPa for M20, M30 and M40, respectively, compared with 23.80, 34.85 and 43.90 MPa for the control mixtures. • Replacing cement with 15% silica fume in the selected 30% RCA mixes produced the highest reported 28-day compressive strengths of 35, 51.5 and 58 MPa for M20, M30 and M40. • Steel-fibre addition improved several reported strength and beam-response indicators, although slump decreased as fibre content increased. • For M40 beams, the ultimate load increased from 75 kN for the control to 95 kN for the 30% RCA–15% silica fume–1.5% fibre mix. The corresponding reported stiffness and energy absorption were also the highest within the M40 series. • The observed gains must be balanced against reduced reported ductility and the inconsistencies identified in the study. Further testing with verified fibre dosage, documented loading geometry, replicate statistics and corrected durability procedures is necessary before structural design adoption.
[1] M. Etxeberria, E. Vázquez, A. Marí, and M. Barra, “Influence of amount of recycled coarse aggregates and production process on properties of recycled aggregate concrete,” Cement and Concrete Research, vol. 37, pp. 735–742, 2007. [2] M. Malešev, V. Radonjanin, and S. Marinković, “Recycled concrete as aggregate for structural concrete production,” Sustainability, vol. 2, 2010. [3] A. M. Wagih, H. Z. El-Karmoty, M. Ebid, and S. H. Okba, “Recycled construction and demolition concrete waste as aggregate for structural concrete,” HBRC Journal, vol. 9, pp. 193–200, 2013. [4] A. Barbudo, J. de Brito, L. Evangelista, M. Bravo, and F. Agrela, “Influence of water-reducing admixtures on the mechanical performance of recycled concrete,” Journal of Cleaner Production, 2013. [5] A. Abbas et al., “Durability of recycled aggregate concrete designed with equivalent mortar volume method,” Cement and Concrete Composites, vol. 31, pp. 555–563, 2009. [6] I. Ajibola, T. Jian Yang, and S. Dirar, “Enhancing the performance of recycled aggregate concrete with microsilica,” International Journal of Structural and Civil Engineering Research, vol. 4, pp. 347–353, 2015. [7] Y. V. Akbari, N. K. Arora, and M. D. Vakil, “Effect on recycled aggregate on concrete properties,” International Journal of Earth Sciences and Engineering, vol. 4, pp. 924–928, 2011. [8] C. S. Das and T. Dey, “Performance evaluation of polypropylene fibre reinforced recycled aggregate concrete,” Construction and Building Materials, vol. 189, pp. 649–659, 2017. [9] H. R. Chaboki and M. Ghalenovi, “Experimental study on the flexural behaviour and ductility ratio of steel fibres coarse recycled aggregate concrete beams,” Construction and Building Materials, vol. 186, pp. 400–422, 2018. [10] I. Maruyama, M. Sogo, T. Sogabe, R. Sato, and K. Kawai, “Flexural properties of reinforced recycled concrete beams,” Hiroshima University, Japan, 2004.
Publication Date
11/13/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...