Civil Engineering Department
P.E.S College of Engineering, Chhatrapati Sambhajinagar, M.S.
Civil Engineering Department
P.E.S College of Engineering, Chhatrapati Sambhajinagar, M.S.
Concrete is widely used in structural construction, but sustained elevated temperature can cause dehydration of cement paste, thermal incompatibility, cracking, spalling and loss of mechanical capacity. This study experimentally evaluates fly ash concrete subjected to 200°C, 400°C, 600°C, 800°C and 1000°C for four hours and subsequently cooled by gradual, intermittent or sudden water cooling. A reference mixture and 5%, 10%, 15%, 20%, 25% and 30% fly ash replacement levels were investigated using a base proportion of 1:2.5:4.0 and water-cement ratio of 0.45. Workability was measured by slump, while residual compressive, split tensile and flexural strengths were determined after 90 days of curing and thermal exposure. The 25% fly ash mixture provided the most favourable overall mechanical response. Under gradual cooling, the 25% mixture recorded 35.56, 34.00, 32.67, 9.88 and 4.00 MPa compressive strengths at 200°C, 400°C, 600°C, 800°C and 1000°C, respectively. Corresponding split tensile strengths were 4.27, 4.19, 3.93, 3.59 and 3.10 MPa, while flexural strengths were 5.60, 5.40, 5.13, 4.93 and 4.70 MPa. Gradual cooling consistently provided the highest residual performance, intermittent cooling was intermediate, and sudden cooling produced the greatest deterioration. The results demonstrate that cooling history should be considered along with maximum temperature and binder composition in post-heating assessment of concrete.
KEYWORDS
1. The base concrete proportion of 1:2.5:4.0 with a water-cement ratio of 0.45 produced a reported slump of 60 mm. 2. Fly ash replacement influenced mechanical performance at ambient and elevated temperatures, with 25% replacement providing the most favourable overall response within the investigated range. 3. Sustained elevated temperature caused progressive deterioration in compressive, split tensile and flexural strength, becoming pronounced at approximately 600°C and severe at 800°C and 1000°C. 4. The 25% fly ash mixture retained comparatively high residual compressive strength at 200°C and 400°C under gradual cooling. 5. Gradual cooling generally produced the highest residual strength, intermittent cooling produced intermediate performance and sudden cooling produced the greatest deterioration. 6. The stronger deterioration under sudden cooling is associated with thermal shock and severe thermal gradients that can induce additional cracking and spalling. 7. Post-heating cooling history should be considered during residual assessment of fire-exposed concrete; maximum temperature alone does not completely define final material condition.
[1] Krzemien K., Hager I., “Post-fire assessment of mechanical properties of concrete with the use of the impact-echo method.,” Construction and Building Materials, 2015;96:155–163. [2] Akcaozoglu K., “Microstructural examination of concrete exposed to elevated temperature by using plane-polarized transmitted light method.,” Construction and Building Materials, 2013;48:772–779. [3] Kodur V.K.R., Naser M.Z., “Structural fire engineering.,” McGraw-Hill Professional, 2020. [4] Sarshar R., Khoury G.A., “Material and environmental factors influencing the compressive strength of unsealed cement paste and concrete at high temperatures.,” Magazine of Concrete Research, 1993;45:51–61. [5] Poon C., Azhar S., Anson M., Wong Y.L., “Comparison of the strength and durability performance of normal-and high-strength pozzolanic concretes at elevated temperatures.,” Cement and Concrete Research, 2001;31:1291–1300. [6] Annerel E., “Assessment of the residual strength of concrete structures after fire exposure.,” PhD thesis, Ghent University, 2010. [7] Czoboly O., Lublóy É., Hlavička V., et al., “Fibers and fiber cocktails to improve fire resistance of concrete.,” Journal of Thermal Analysis and Calorimetry, 2017;128:1453–1461. [8] Peng G.F., Bian S.H., Guo Z.Q., Zhao J., Peng X.L., Jiang Y.C., “Effect of thermal shock due to rapid cooling on residual mechanical properties of fiber concrete exposed to high temperatures.,” Construction and Building Materials, 2008;22:948–955. [9] Yermak N., Pliya P., Beaucour A.L., Simon A., Noumowé A., “Influence of steel and/or polypropylene fibres on the behaviour of concrete at high temperature: spalling, transfer and mechanical properties.,” Construction and Building Materials, 2017;132:240–250. [10] Ergun A., Kurklu G., Serhat B.M., Mansour M.Y., “The effect of cement dosage on mechanical properties of concrete exposed to high temperatures.,” Fire Safety Journal, 2013;55:160–167.
Publication Date
8/25/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
2
Total views since publication
PDF Downloads
3
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...