Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM65439
Volume:
10 |
6 |
Jun 2026
Pages:
1-8
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Computer Engineering
Zeal College of Engineering and Research
Computer Engineering
Zeal College of Engineering and Research
Computer Engineering
Zeal College of Engineering and Research
Computer Engineering
Zeal College of Engineering and Research
Computer Engineering
Zeal College of Engineering and Research
Manual monitoring of intravenous (IV) fluid bags in hospitals remains prone to delays, overflow events, and adverse patient outcomes, particularly in understaffed or rural facilities. This paper presents FLUIDCARE, a working prototype with a production-oriented architecture for real-time fluid-bag weight monitoring; components remaining for deployment are enumerated in Section VII. The architecture comprises ESP32-based sensor nodes equipped with HX711 24-bit analog-to-digital converters and single-point load cells, a repeater relay layer for range extension, a master gateway that bridges ESP-NOW to MQTT over TLS, and a Django/Channels backend with Redis-backed signal processing and a React dashboard. We detail the complete signal pipeline: on-device interquartile-range (IQR) median filtering, a calibrated linear weight con- version (m = 1.18721 × 10−3 g/count, b = 683.22 g), server-side monotonic-depletion validation, and exponentially weighted moving average (EWMA) smoothing (α = 0.2). Calibration experiments conducted over 13 reference masses spanning 0– 575 g and N = 7,855 raw observations yield R2 = 0.9995, RMSE = 3.47 g, and MAE = 2.87 g. The device exhibits short-term repeatability of ±1–2 g (1σ) and an absolute calibration accuracy of RMSE = 3.47 g (MAE = 2.87 g) across the 0– 575 g range. We further describe the threshold-based alert subsystem, the WebSocket real-time broadcast pipeline, and a multi-tenant hospital data model supporting floors, wards, beds, and patients. Four open prototype limitations are discussed, along with directions for future work.
KEYWORDS
This paper presented FLUIDCARE, a working prototype of a multi-tier IoT system for real-time hospital fluid-bag monitoring, with a production-oriented architecture; com-ponents remaining for deployment are enumerated in Sec-tion VIII. The four-tier architecture connects sensor nodes, a repeater mesh, and a master gateway through ESP-NOW, and bridges to the cloud via MQTT over TLS. A two-tier signal pipeline—on-device IQR-median filtering followed by server-side monotonic-depletion validation and EWMA smoothing—provides robust noise rejection for clinical envi-ronments. Calibration over 7,855 observations across 13 ref-erence masses confirms a linear sensor model (R2 = 0.9995, RMSE = 3.47 g, MAE = 2.87 g, both in-sample) with short- term repeatability of ±1–2 g (1σ) and absolute calibration accuracy of RMSE = 3.47 g. The 1 g change-detection threshold implemented in firmware is supported by the post-filter noise floor. Four prototype defects have been identified and described in Section VIII: light-load and above-range cal-ibration limitations, unimplemented blood/urine alert dispatch, the absence of a refill-detection mechanism, and the per-master scalability ceiling.
[1] M. McLellan, R. Hayes, and F. Carter, “Clinical Utility of the Fluid Intravenous Alert Monitor,” Journal of Clinical Anesthesia, Elsevier, 2016. [2] J. Park, S. B. You, and H. Kim, “Experience of Nurses with Intravenous Fluid Monitoring for Patient Safety: A Qualitative Descriptive Study,” PLOS ONE, 2022. [3] M. Moovendan, R. Jeyaprakash, and K. Jayanthi, “Design of Automated Control and Monitoring System for Intravenous Infusion Based on IoT,” in Proc. IEEE ICCPCT, 2023. [4] A. Paranthaman and K. Annalakshmi, “IV Fluid Bag Monitoring, Alert, and Control System Using ESP32 and IoT,” Int. J. Scientific Advances in Technology (IJSAT), 2025. [5] H. Patil, S. Deshmukh, and P. Kulkarni, “IVigilance – IoT Based Intravenous Drip Monitoring and Controlling System,” Int. J. Creative Research Thoughts (IJCRT), 2024. [6] W. S. Nimi, M. Joseph, and T. Kurian, “Reliable and Smart E-Healthcare System for IV Fluid and Vital Parameter Monitoring,” IEEE J. Transla-tional Engineering in Health and Medicine, 2022. [7] D. Ghosh, S. Dutta, and R. Nath, “Smart Saline Level Monitoring System Using ESP-32 and MQTT-S,” in Proc. IEEE Healthcom, 2022. [8] X. Bai, J. Liu, and Y. Zhang, “Application of Infusion Control System Based on Internet of Things Technology,” J. Healthcare Engineering, 2021. [9] N. Giaquinto, L. Romano, and M. Rossi, “Real-Time Drip Infusion Monitoring Through a Computer Vision System,” IEEE Trans. Biomedical Engineering, 2020.
Publication Date
6/25/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
4
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...