Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM67864
Volume:
10 |
10 |
Oct 2026
Pages:
1-7
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Electronic & Telecommunication Engineering.
JSMP Bhivrabai Sawant Polytechnic
Electronic & Telecommunication Engineering.
JSMP Bhivrabai Sawant Polytechnic
Electronic & Telecommunication Engineering.
JSMP Bhivrabai Sawant Polytechnic
Electronic & Telecommunication Engineering.
JSMP Bhivrabai Sawant Polytechnic
Electronic & Telecommunication Engineering.
JSMP Bhivrabai Sawant Polytechnic
The IoT-Based Hospital Gas Leakage Alert System is designed to detect and monitor hazardous gas leakage in hospitals and provide immediate alerts to prevent accidents. Hospitals use medical gases such as oxygen and nitrous oxide for patient treatment and medical procedures. Gas leakage can create serious safety risks, including fire hazards, explosions, and harmful exposure. The proposed system uses gas sensors to monitor gas concentration continuously. A microcontroller processes the sensor readings and compares them with a predefined safety limit. When the gas concentration exceeds this limit, the system activates a buzzer and warning indicators and sends an alert through an IoT platform. This system helps hospital staff respond quickly and improves the safety of patients and medical personnel.
KEYWORDS
The IoT-Based Hospital Gas Leakage Alert System offers a practical approach to monitoring gas leakage risks in hospital environments. By combining gas sensors, a microcontroller, local alarm devices, and IoT communication, the system is designed to identify abnormal gas levels and notify hospital personnel promptly. Its continuous monitoring and remote notification capabilities can help reduce response time and support hospital safety management. The system can be enhanced through additional sensors, cloud monitoring, backup power, and carefully engineered automatic control features. For real hospital deployment, it must be used alongside appropriate certified safety equipment and established emergency procedures.
[1] S. B. Patil and V. K. Sawant, "Borewell rescue robot with multi-tier monitoring system," Int. J. Adv. Res. Comput. Commun. Eng., vol. 6, no. 5, pp. 320–325, 2017. [2] P. Arun Kumar, S. Ramesh, and T. Balaji, "Automated child rescue from borewell using embedded system," Int. Res. J. Eng. Technol., vol. 5, no. 4, pp. 1203–1208, 2018. [3] K. Saran, M. Sivasankari, and N. Santhiya, "Borewell rescue robot with pneumatic arm mechanism," Int. J. Innov. Res. Sci. Eng. Technol., vol. 7, no. 3, pp. 2489–2495, 2018. [4] M. V. D. Prasad and B. L. Raju, "Design and implementation of child rescue system in borewell," Int. J. Pure Appl. Math., vol. 118, no. 20, pp. 411–418, 2018. [5] G. John and M. S. Deepa, "IoT based smart borewell child saver robot," Int. J. Sci. Res. Comput. Sci. Eng. Inf. Technol., vol. 5, no. 2, pp. 98–104, 2019. [6] R. Palanisamy, D. Palanikkumar, and V. Rajasekar, "Design and development of smart borewell rescue robot using microcontroller," J. Critical Rev., vol. 7, no. 14, pp. 245–250, 2020. [7] P. Ramesh, S. Logesh, and D. Murugan, "Borewell child rescue system with integrated oxygen supply," IJSRST, vol. 4, no. 2, pp. 612–617, 2018. [8] A. S. Sharan, K. Preethi, and M. G. Kumar, "Design of autonomous borewell rescue robot using wireless sensor network," Int. J. Eng. Adv. Technol., vol. 9, no. 1, pp. 4810–4815, 2019. [9] K. S. Babu, V. H. Reddy, and N. M. Kumar, "Child detection in borewell using OpenCV," IJIRSET, vol. 8, no. 3, pp. 2351–2357, 2019. [10] D. Nithya, T. Saranya, and P. Gayathri, "Early detection and alert system for borewell accidents," IJECS, vol. 6, no. 8, pp. 22134–22138, 2017.
Publication Date
10/12/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
2
Total views since publication
PDF Downloads
8
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...