Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM38574
Volume:
8 |
11 |
Nov 2024
Pages:
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
The HVDC system is a viable option, particularly for long-distance transmission. Electrical transmission systems are susceptible to short circuit problems, resulting in excessive current that can ultimately damage the system’s equipment. Consequently, the system necessitates prompt repair to reinstate power transmission and ensure system safety. Therefore, the aim of this study is to create a model that can accurately determine the fault’s position. The objective of the effort is to develop a model that yields precise findings while also being collectively optimal. A bipolar transmission line, measuring 814 km in length, operates at 700 kV and has the capacity to transmit 1500 MW of electricity, constructed using PSCAD/EMTDC software in accordance with CIGRÉ benchmark requirements. The constructed model is subsequently simulated for a short circuit defect with an ON resistance of 0.01 Ω and an OFF resistance of 1.0 x 10^6 Ω, altering the fault location along the transmission line at 1 km intervals. The collected data was processed for feature extraction. Data from both terminals of the transmission line is utilized for the training and evaluation of deep neural network models. The assessment of the suggested system was conducted based on the mean squared error and the accuracy of fault estimation. The suggested system demonstrates superior performance compared to current baseline methods.
KEYWORDS
Publication Date
12/10/2024
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
3
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...