Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM69308
Volume:
10 |
11 |
Nov 2026
Pages:
1-4
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI
Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI
Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI
Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI
Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI

Department of Civil Engineering
P.R.POTE PATIL COLLEGE OF ENGINEERING & MANAGEMENT, AMRAVATI
Corrosion of steel reinforcement is a major durability concern in reinforced concrete (RC), particularly in humid and chloride-rich environments. This study evaluates sacrificial anode cathodic protection using zinc and aluminium anodes connected to reinforcement cages and exposed to a simulated saline environment. A specific feature of the investigation is the application of a porous mortar coating to the anodes, including aluminium, to examine whether the coating can modify environmental exposure and potentially delay the formation of the passive aluminium oxide film. Zinc and aluminium anodes were prepared by sand casting. The project report describes circular anodes with a diameter of 6 cm and a thickness of 2.5 cm, with a porous mortar layer of approximately 1 cm applied to all sides. Rebar cages were immersed in saline water, and half-cell potential readings were recorded daily using a silver–silver reference electrode and a multimeter. The observations showed that after approximately 3–4 days, the protected specimens exhibited more negative readings near the anodes and less negative readings at the reinforcement than at the anodes. Visual inspection during the experimental period did not identify visible corrosion on the protected rebar cages. Comparison of the two anode materials indicated slightly better performance for aluminium than zinc under the tested conditions. The findings provide preliminary evidence that mortar-coated sacrificial anodes can contribute to corrosion mitigation; longer-duration and controlled testing is required to establish their service life and the influence of coating thickness.
KEYWORDS
The experimental investigation indicates that zinc and aluminium sacrificial anodes can provide corrosion protection to reinforcement under the simulated saline exposure conditions used in this project. The more negative readings observed near the anodes, together with less negative readings at the reinforcement, were interpreted as evidence of preferential anode oxidation and cathodic protection. Aluminium showed slightly superior observed performance compared with zinc in the reported test. Visual observations also found no visible corrosion on the protected reinforcement cages during the test period, whereas the specimen without an anode showed further corrosion. The application of a porous mortar coating to the anodes, including aluminium, represents the principal approach investigated in this project to modify anode exposure and potentially delay aluminium passivation. The results are preliminary: they demonstrate the behaviour observed in the laboratory setup but do not establish long-term service life, optimum coating thickness or performance on large structural areas.
[1] P. Astuti, R. S. Rafdinal, H. Hamada, Y. Sagawa, D. Yamamoto, and K. Kamarulzaman, “Effectiveness of rusted and non-rusted reinforcing bar protected by sacrificial anode cathodic protection in repaired patch concrete,” IOP Conference Series: Earth and Environmental Science, vol. 366, no. 1, p. 012013, 2019. [2] NACE RP0100, Cathodic Protection of Prestress Concrete Cylinder Pipeline, 2000. [3] BS EN ISO 12696, Cathodic Protection of Steel in Concrete, 2012. [4] C. Christodoulou, C. I. Goodier, S. A. Austin, G. K. Glass, and J. Webb, “A new arrangement of galvanic anodes for the repair of reinforced concrete structures,” Construction and Building Materials, vol. 50, pp. 300–307, 2014. [5] S. P. Holmes, G. D. Wilcox, P. J. Robins, G. K. Glass, and A. C. Roberts, “Responsive behavior of galvanic anodes in concrete and the basis for its utilization,” Corrosion Science, vol. 53, no. 10, pp. 3450–3454, 2011. [6] S. Kainuma, M. Yang, S. Ishihara, A. Kaneko, and T. Yamauchi, “Corrosion protection of steel members using an Al-Zn base sacrificial anode and fiber sheet in an atmospheric environment,” Construction and Building Materials, vol. 224, pp. 880–893, 2019. [7] V. Rajendran and R. Murugesan, “Study on performance of self-regulating sacrificial galvanic anodes with and without preconditioning against control specimen and using accelerated corrosion,” 2013. [8] A. A. Sagüés and R. G. Powers, “Sprayed-zinc sacrificial anodes for reinforced concrete in marine service,” Corrosion, vol. 52, no. 7, pp. 508–522, 1996.
Publication Date
11/21/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
4
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...