Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM68879
Volume:
10 |
11 |
Nov 2026
Pages:
1-10
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Department of Civil Engineering
Kongunadu College of Engineering and Technology (Autonomous), Tiruchirappalli
Department of Civil Engineering
Kongunadu College of Engineering and Technology (Autonomous), Tiruchirappalli
Department of Civil Engineering
Kongunadu College of Engineering and Technology (Autonomous), Tiruchirappalli
Department of Civil Engineering
Kongunadu College of Engineering and Technology (Autonomous), Tiruchirappalli
This study presents a preliminary structural design of a ground-plus-two-storey reinforced concrete residential building by combining three-dimensional modelling in STAAD.Pro V8i with manual limit-state design. One-way and two-way slabs, a T-beam, columns under uniaxial and biaxial bending, an isolated footing, and a dog-legged staircase were assessed under factored gravity loads using IS 456:2000. The member calculations adopted M25 concrete and reinforcement with a nominal yield strength of 500 MPa. Minimum reinforcement governed the one-way slab, for which 201 mm²/m was provided against a minimum of 150 mm²/m. The two-way slab had a calculated shear stress of 0.14 MPa and a span-to-effective-depth ratio of 27.9, compared with the reported limits of 0.37 MPa and 32, respectively. The representative beam had a calculated factored bending moment of 123.9 kN·m and a shear force of 117.2 kN. For the 1.50 m square isolated footing, the service bearing pressure due to the column load alone was 186.7 kPa against an assumed allowable bearing pressure of 200 kPa. The results document the preliminary gravity-load design of selected members. Building-level assessment requires verification of the biaxial column interaction, reconciliation of the footing depth and shear calculations, and evaluation of the seismic response of the three-dimensional model
KEYWORDS
This study combined three-dimensional modelling in STAAD.Pro V8i with manual limit-state calculations to document the preliminary gravity-load design of a ground-plus-two-storey reinforced concrete residential building. The calculations identified the governing criteria for selected members and quantified the difference between required and provided reinforcement. Minimum reinforcement governed the one-way slab, for which 201 mm²/m was provided against a minimum requirement of 150 mm²/m. The two-way slab developed a calculated shear stress of 0.14 MPa against a reported resistance of 0.37 MPa. Its span-to-effective-depth ratio was 27.9, below the adopted limit of 32. For the 1.50 m square isolated footing, the calculated service bearing pressure was 186.7 kPa against an assumed allowable pressure of 200 kPa. This estimate accounts for the column load alone. The footing reinforcement provided approximately 377 mm²/m in each direction against the reported requirement of 332 mm²/m. These findings apply to the selected members under the adopted gravity-load assumptions. The biaxial column interaction requires verification of the limiting moments about both axes. The footing assessment requires a consistent effective depth for the flexural, one-way shear, and punching shear checks, together with site-specific confirmation of the allowable bearing pressure. Although seismic loading was defined in the model, the reported results establish only the preliminary gravity-load design basis. A building-level assessment requires documented lateral response, governing load combinations, and verification of ductile detailing.
[1] Bureau of Indian Standards, Plain and Reinforced Concrete—Code of Practice, 4th rev., IS 456:2000. New Delhi, India, 2000. standards.bis.gov.in [2] Bureau of Indian Standards, Code of Practice for Design Loads (Other Than Earthquake) for Buildings and Structures—Part 1: Dead Loads—Unit Weights of Building Materials and Stored Materials, 2nd rev., IS 875 (Part 1):1987. New Delhi, India, 1987. 1987 Indian St [3] Bureau of Indian Standards, Code of Practice for Design Loads (Other Than Earthquake) for Buildings and Structures—Part 2: Imposed Loads, 2nd rev., IS 875 (Part 2):1987. New Delhi, India, 1987. bis.gov.in [4] Bureau of Indian Standards, Criteria for Earthquake Resistant Design of Structures—Part 1: General Provisions and Buildings, 6th rev., IS 1893 (Part 1):2016. New Delhi, India, 2016. bis.gov.in [5] Bureau of Indian Standards, Design Aids for Reinforced Concrete to IS 456:1978, SP 16:1980. New Delhi, India, 1980. bnec.ac.in [6] Bureau of Indian Standards, Ductile Design and Detailing of Reinforced Concrete Structures Subjected to Seismic Forces—Code of Practice, 1st rev., IS 13920:2016. New Delhi, India, 2016. BIS [7] Bureau of Indian Standards, Code of Practice for Design Loads (Other Than Earthquake) for Buildings and Structures—Part 5: Special Loads and Load Combinations, 2nd rev., IS 875 (Part 5):1987. New Delhi, India, 1987. services.bis.gov.in [8] Bentley Systems, STAAD.Pro V8i [structural analysis and design software]. Communities [9] G. T. Naidu, K. Devi, V. Dunesh, D. B. Prasad, M. C. Naga Sai, and V. G. Yedla, “Planning, designing and estimation of G+2 residential building using AutoCAD and STAAD PRO,” International Journal for Research in Applied Science & Engineering Technology, vol. 12, no. 4, pp. 205–207, 2024. DOI. www.ijraset.com [10] M. M. Mabula, M. Taki, J. Mize, D. Dutta, M. Deka, J. Doni, and N. Goswami, “Comparison between manual and software approach towards analysis and design of a residential building,” International Journal for Research in Applied Science & Engineering Technology, vol. 11, no. 6, pp. 4488–4499, 2023. DOI. ijraset.com
Publication Date
11/11/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
1
Total views since publication
PDF Downloads
6
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...