Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM42848
Volume:
9 |
3 |
Mar 2025
Pages:
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
The root cause for the premature failure of a reheater tube bend of a 700 MW supercritical boiler after 15000 hrs of service was investigated. The chemical composition, mechanical properties, and microstructural degradation have been studied both on the failed and virgin tube material. The mechanisms involved in the failure process have been identified and the methodology to be followed for preventing recurrence of the incidence has been brought out.
KEYWORDS
Publication Date
3/28/2025
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
3
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.