This paper presents literature review on structural health assessment and retrofitting of heritage structures using Non-Destructive Testing (NDT) techniques. The study synthesizes global research trends, deterioration mechanisms, diagnostic tools, retrofitting strategies, and structural health monitoring approaches applicable to stone, masonry, and reinforced concrete heritage structures. A detailed academic framework is developed with reference to rock-cut basalt monuments such as the Pataleshwar Temple in Pune, India.
KEYWORDS
In conclusion, the assessment and retrofitting of heritage structures require a balanced approach that combines modern engineering techniques with conservation principles. Methods such as visual inspection, material characterization, statistical analysis, and non-destructive testing (NDT) play a crucial role in understanding structural condition without causing damage. Effective conservation depends on integrating these techniques to ensure accurate evaluation and informed decision-making. At the same time, engineering interventions must follow key principles like minimum intervention, reversibility, and material compatibility to protect the original character of the structure. Overall, a scientific, careful, and sustainable approach is essential to maintain the structural safety, historical authenticity, and cultural value of heritage structures for future generations.
[1] IS 13311 (Part 2): 1992, Non-Destructive Testing of Concrete – Rebound Hammer. [2] R. Jones, 'Non-Destructive Testing of Concrete,' Cambridge University Press, 2018. [3] A. Binda et al., 'Non-destructive investigation in masonry structures,' Construction and Building Materials, 2019. [4] P. Lourenço, 'Recommendations for heritage structural assessment,' Engineering Structures, 2016. [5] ASTM C805/C805M-18, Rebound Number of Hardened Concrete. [6] M. Solla et al., 'GPR applications in historic structures,' Journal of Applied Geophysics, 2015. [7] D. Aggelis, 'Acoustic emission in concrete structures,' Construction and Building Materials, 2011. [8] RILEM TC 154-EMD, 'Electrochemical Methods for Diagnosis of Corrosion.' [9] F. Boschi et al., 'Thermography in heritage diagnostics,' Infrared Physics & Technology, 2013. [10] C. Gentile and A. Saisi, 'Ambient vibration testing of historic structures,' Engineering Structures, 2007.
Publication Date
5/19/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...