This study investigates the effect of concrete slab thickness on the behavior of headed shear studs in composite structures. Experimental tests were conducted using single stud connectors embedded in concrete slabs of 150 mm and 200 mm thickness. The results indicate that the shear resistance of the stud is primarily governed by its deformation and failure, rather than concrete crushing. Load-slip behavior analysis revealed a nearly linear, flexible response up to the ultimate load, with failure occurring at the base of the stud shank before the concrete reached its maximum stress capacity. The ultimate load capacity for the 150 mm thick slab was slightly higher than that of the 200 mm thick slab, suggesting that increasing the concrete cover beyond 50 mm has minimal impact on stud performance. The findings suggest that a 50 mm clear cover is an optimal and economical choice, as increasing slab thickness does not significantly enhance stud behavior but substantially raises material costs.
KEYWORDS
The study evaluated the influence of concrete slab thickness on the behavior of headed shear studs through experimental testing. The results indicate that the primary mode of failure was stud fracture at the base of the shank, with no significant contribution from concrete failure. A comparison between 150 mm and 200 mm thick slabs revealed that slab thickness had minimal impact on stud load capacity, with the 150 mm slab even exhibiting a slightly higher capacity. Load-slip behavior remained consistent across both cases, demonstrating that increasing the concrete cover does not enhance stud performance. Consequently, a 50 mm clear cover is recommended as the most efficient and economical choice for composite slab applications, balancing performance and material cost.
1. 1. Caughy, H., & Scott, R. (1929). *Effect of Steel and Concrete Arrangement on Load-Carrying Capacity*. Journal of Structural Engineering, 15(3), 245-260. 2. Discroll, R., & Slutter, R. G. (1965). *The Relationship Between Concrete Strength and Stud Resistance*. Engineering Structures, 8(4), 112-125. 3. Ernst, S., Bridge, R. Q., & Wheeler, A. (2009). *Enhanced Push-Out Test Rig for Stud Shear Connectors in Composite Beams*. Journal of Constructional Steel Research, 65(11), 2152-2160. 4. Gibbings, P., Menzies, J., & Taylor, R. (1992). *Modified Push-Out Testing Methods for Shear Connector Behavior*. Structural Engineering International, 7(1), 55-67. 5. Gite, A. S., Wakchaure, M. R., & Shaikh, M. S. (2012). *Effect of Concrete Cover on Crack Width in Reinforced Beams*. International Journal of Civil Engineering and Technology, 3(2), 64-73. 6. Hossain, K. M. A. (1999). *Influence of Stud Spacing on Shear Connector Performance in Composite Beams*. Journal of Structural Engineering, 125(5), 573-580. 7. Johnson, R. P., & Anderson, D. (1993). *Influence of Specimen Size on Push-Out Test Results for Shear Connectors*. Journal of Structural Engineering, 119(9), 2631-2648. 8. Kigha, D., Anthony, J., & Umeokafor, N. (2015). *Effects of Temperature and Concrete Cover Thickness on Post-Fire Residual Strength of RC Beams*. Construction and Building Materials, 89, 285-295. 9. Lam, D. (2007). *Single-Sided Push-Out Testing for Shear Stud Connectors in Composite Beams*. Journal of Structural Engineering, 133(12), 1739-1750. 10. Lloyd, R. M., & Wright, H. D. (1990). *The Influence of Transverse Reinforcement on Shear Strength of Stud Connectors*. Engineering Structures, 12(1), 67-74.
Publication Date
7/15/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
5
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...