Multi-storied buildings are increasingly common due to rising land costs and space scarcity in urban areas. This paper presents the planning, analysis and design of an earthquake-resistant, 16-storied, 5-star hotel building located in seismic zone III. Functional planning was carried out to satisfy the requirements of the National Building Code 2005, applicable state building rules, and hotel-rating criteria specified by the Ministry of Tourism, Government of India. Structural modeling, analysis and design were performed using SAP2000 based on the limit state method of IS 456:2000, with loads estimated as per IS 875 (Parts I-III) and seismic forces computed by the equivalent static method of IS 1893 (Part I). Design results obtained from the software for representative beams, columns, slabs and staircases were validated through independent manual calculations, and ductile detailing was carried out as per IS 13920:1993. The manual and software-based results were found to be in close agreement, confirming the reliability of the software-based design.
KEYWORDS
The planning, analysis and design of a 16-storied, earthquake-resistant, 5-star hotel building have been carried out successfully. Functional and structural planning satisfied NBC 2005 and hotel-rating requirements, and drawings were prepared using AutoCAD. Structural analysis and design were performed using SAP2000 and independently verified by manual calculation for representative beams, columns, slabs, staircases and the pile foundation; the manual and software results were found to be in close agreement. Ductile detailing of all members was carried out as per IS 13920:1993 to improve seismic performance. It is noted that, while the design substantially improves earthquake resistance, no structure can be rendered completely immune to earthquake effects.
1. Government of India, Department of Tourism (H & R Division), "Guidelines for Approval & Classification/Re-Classification of Apartment Hotels." 2. Gurcharan Singh, Jagdish Singh, Building Planning, Designing and Scheduling, Standard Publishers Distributors, 2009. 3. M. G. Shah, C. M. Kale, S. Y. Patki, Building Drawing with an Integrated Approach to Built Environment, 4th ed., Tata McGraw-Hill, 2002. 4. Pankaj Agarwal, Manish Shrikhande, Earthquake Resistant Design of Structures, Prentice Hall of India, 2006. 5. S. K. Duggal, Earthquake Resistant Design of Structures, Oxford University Press, 2007. 6. P. C. Varghese, Foundation Engineering, Prentice Hall of India, 2005. 7. S. Unnikrishna Pillai, Devadas Menon, Reinforced Concrete Design, Tata McGraw-Hill, 2003. 8. National Building Code of India, 2005. 9. IS 456:2000, Plain and Reinforced Concrete - Code of Practice, Bureau of Indian Standards. 10. SP:16-1980, Design Aids for Reinforced Concrete to IS 456:1978, Bureau of Indian Standards.
Publication Date
7/8/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
7
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...