Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM34644

SECURE FLOW - “A Life Saving Intravenous Drip System”

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM34644

Volume:

8 |

5 |

May 2024

Pages:

1-3

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM34644

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

SJ

SIRIVANTH J

Department of EEE

Vidya Vikas Institute of Engineering & Technology, Mysuru.

Download Author Certificate
VR

VAISHNAVI R

Department of EEE

Vidya Vikas Institute of Engineering & Technology, Mysuru.

Download Co-Author Certificate
SSB

SACHIN S BHAT

Department of EEE

Vidya Vikas Institute of Engineering & Technology, Mysuru.

Download Co-Author Certificate
SS

SANJAY S

Department of EEE

Vidya Vikas Institute of Engineering & Technology, Mysuru.

Download Co-Author Certificate
MB

MANJUNATHA B

Department of EEE

Vidya Vikas Institute of Engineering & Technology, Mysuru.

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Intravenous (IV) therapy is a common medical procedure that involves the delivery of fluids, medications, or nutrients directly into a vein. Intravenous drips are often used in hospitals and clinics to treat a variety of conditions, including dehydration, sepsis, and chemotherapy. Traditionally, Intravenous drips are controlled manually by healthcare professionals or nurses. In recent years, there has been growing interest in the development of automated Intravenous drip systems. These systems can help to improve the accuracy, efficiency, and safety of Intravenous therapy. The system “Secure flow” is proposed to use solenoid valve to control the flow of fluid, and the load cell is used to measure the weight of the Intravenous bag. If the weight of the Intravenous bag decreases below a certain threshold, the solenoid valve is activated to stop the flow of fluid and also sends an alert notification to the registered number. It also has a potentiometer which can be used to adjust the preset value of the liquid in the solenoid to flow through the patient’s body. Overall, this system has the potential to improve the safety, efficiency, and accuracy of Intravenous therapy. This system can be a valuable tool for hospitals and clinics that are looking to improve the quality of care that they provide to their patients.

KEYWORDS

accuracy efficiency and safety of Intravenous therapy

Cite This Article

SIRIVANTH J, VAISHNAVI R, SACHIN S BHAT, SANJAY S, MANJUNATHA B, "SECURE FLOW - “A Life Saving Intravenous Drip System”," International Journal of Scientific Research in Engineering and Management, vol. 8, no. 5, pp. 1-3, May 2024. https://doi.org/10.55041/IJSREM34644

Full Article/Conclusion

The project “SECURE FLOW: A life saving Intravenous Drip” is a significant advancement in healthcare technology. The proposed project addresses critical issues surrounding Intravenous (IV) drip therapy, aiming to enhance patient safety and minimize complications associated with the IV therapy. The objectives of the project underscore its commitment to secure IV therapy by implementing measures to block reverse blood flow, alert caretakers or nurses when intervention is required, and ultimately improve patient outcomes. By integrating a solenoid valve into the Intravenous drip system, control of the fluid flow is achieved, improving patient safety and treatment accuracy. Automating the Intravenous drip process not only enhances patient safety but also optimizes healthcare efficiency. By reducing the need for manual adjustments and constant supervision, healthcare professionals can focus on other critical tasks, leading to improved patient care and overall workflow. Furthermore, the automated Intravenous drip system can be connected to centralized healthcare systems, enabling seamless integration with patient records and facilitating data analysis. In conclusion, the objective of this project has been accomplished with the help of Embedded Systems. The developed system reduces the Intravenous drip complications such as air embolism in blood veins, reverse flow of blood and blood clots.

References

[1]       Sonkar, N. Pal, H. Gupta and J. K. Dhanoa, "Smart Intravenous Drip Monitoring System with Bubble Detection Indicator using IoT," 2022 2nd International Conference on Intelligent Technologies (CONIT), Hubli, India, 2022, pp. 1-7, doi: 10.1109/CONIT55038.2022.9848118. [2]       R. T. Abbasi, A. Zahoor, L. Junaid, F. Amin and Z. U. Rehman, "Automatic Intravenous Drip Drop Counter and Controller," 2023 3rd International Conference on Digital Futures and Transformative Technologies (ICoDT2), Islamabad, Pakistan, 2023, pp. 1-5, doi:10.1109/ICoDT259378.2023.10325753. [3]       C. -F. Huang and J. -H. Lin, "A warning system based on the RFID technology for running-out of injection fluid," 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA, 2011, pp. 2212-2215, doi: 10.1109/IEMBS.2011.6090418. [4]       A. Cataldo, G. Cannazza, N. Giaquinto, A. Trotta and G. Andria, "Microwave TDR for Real-Time Control of Intravenous Drip Infusions," in IEEE Transactions on Instrumentation and Measurement, vol. 61, no. 7, pp. 1866-1873, July 2012, doi: 10.1109/TIM.2012.2192346. [5]       R. Maniktalia, S. Tanwar, R. Billa and D. K, "IoT Based Drip Infusion Monitoring System," 2022 IEEE Delhi Section Conference (DELCON), New Delhi, India, 2022,    pp.   1-6, doi:10.1109/DELCON54057.2022.9753052.

Editorial & Review Transparency

Publication Date

5/29/2024

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

0

Total views since publication

PDF Downloads

46

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.