Loading article...
Loading article...
Stream/Area:
-
Subject:
-
Paper ID:
IJSREM34644
Volume:
8 |
5 |
May 2024
Pages:
1-3
Publication Frequency:
Monthly (12 issues per year)
License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.
Department of EEE
Vidya Vikas Institute of Engineering & Technology, Mysuru.
Department of EEE
Vidya Vikas Institute of Engineering & Technology, Mysuru.
Department of EEE
Vidya Vikas Institute of Engineering & Technology, Mysuru.
Department of EEE
Vidya Vikas Institute of Engineering & Technology, Mysuru.
Department of EEE
Vidya Vikas Institute of Engineering & Technology, Mysuru.
Intravenous (IV) therapy is a common medical procedure that involves the delivery of fluids, medications, or nutrients directly into a vein. Intravenous drips are often used in hospitals and clinics to treat a variety of conditions, including dehydration, sepsis, and chemotherapy. Traditionally, Intravenous drips are controlled manually by healthcare professionals or nurses. In recent years, there has been growing interest in the development of automated Intravenous drip systems. These systems can help to improve the accuracy, efficiency, and safety of Intravenous therapy. The system “Secure flow” is proposed to use solenoid valve to control the flow of fluid, and the load cell is used to measure the weight of the Intravenous bag. If the weight of the Intravenous bag decreases below a certain threshold, the solenoid valve is activated to stop the flow of fluid and also sends an alert notification to the registered number. It also has a potentiometer which can be used to adjust the preset value of the liquid in the solenoid to flow through the patient’s body. Overall, this system has the potential to improve the safety, efficiency, and accuracy of Intravenous therapy. This system can be a valuable tool for hospitals and clinics that are looking to improve the quality of care that they provide to their patients.
KEYWORDS
The project “SECURE FLOW: A life saving Intravenous Drip” is a significant advancement in healthcare technology. The proposed project addresses critical issues surrounding Intravenous (IV) drip therapy, aiming to enhance patient safety and minimize complications associated with the IV therapy. The objectives of the project underscore its commitment to secure IV therapy by implementing measures to block reverse blood flow, alert caretakers or nurses when intervention is required, and ultimately improve patient outcomes. By integrating a solenoid valve into the Intravenous drip system, control of the fluid flow is achieved, improving patient safety and treatment accuracy. Automating the Intravenous drip process not only enhances patient safety but also optimizes healthcare efficiency. By reducing the need for manual adjustments and constant supervision, healthcare professionals can focus on other critical tasks, leading to improved patient care and overall workflow. Furthermore, the automated Intravenous drip system can be connected to centralized healthcare systems, enabling seamless integration with patient records and facilitating data analysis. In conclusion, the objective of this project has been accomplished with the help of Embedded Systems. The developed system reduces the Intravenous drip complications such as air embolism in blood veins, reverse flow of blood and blood clots.
[1] Sonkar, N. Pal, H. Gupta and J. K. Dhanoa, "Smart Intravenous Drip Monitoring System with Bubble Detection Indicator using IoT," 2022 2nd International Conference on Intelligent Technologies (CONIT), Hubli, India, 2022, pp. 1-7, doi: 10.1109/CONIT55038.2022.9848118. [2] R. T. Abbasi, A. Zahoor, L. Junaid, F. Amin and Z. U. Rehman, "Automatic Intravenous Drip Drop Counter and Controller," 2023 3rd International Conference on Digital Futures and Transformative Technologies (ICoDT2), Islamabad, Pakistan, 2023, pp. 1-5, doi:10.1109/ICoDT259378.2023.10325753. [3] C. -F. Huang and J. -H. Lin, "A warning system based on the RFID technology for running-out of injection fluid," 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA, 2011, pp. 2212-2215, doi: 10.1109/IEMBS.2011.6090418. [4] A. Cataldo, G. Cannazza, N. Giaquinto, A. Trotta and G. Andria, "Microwave TDR for Real-Time Control of Intravenous Drip Infusions," in IEEE Transactions on Instrumentation and Measurement, vol. 61, no. 7, pp. 1866-1873, July 2012, doi: 10.1109/TIM.2012.2192346. [5] R. Maniktalia, S. Tanwar, R. Billa and D. K, "IoT Based Drip Infusion Monitoring System," 2022 IEEE Delhi Section Conference (DELCON), New Delhi, India, 2022, pp. 1-6, doi:10.1109/DELCON54057.2022.9753052.
Publication Date
5/29/2024
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
46
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...