Electrical networks are exposed to environmental conditions that may contribute to insulation deterioration, equipment damage, and unsafe operating conditions. This paper presents a low-voltage educational model for demonstrating environmental hazard sensing and relay-based load isolation. The proposed arrangement combines a rain/moisture sensor and an infrared (IR) flame sensor with two relay channels. Sensor-module outputs, generated according to their configured thresholds, are intended to actuate the corresponding relay channel and disconnect a demonstration load. The design illustrates a hardware-oriented sensing and switching concept without requiring a programmable microcontroller. The paper describes the system architecture, component functions, operating sequence, design considerations, and validation plan. The supplied project documents do not contain measured response-time, accuracy, or repeatability data; therefore, the discussion distinguishes expected operation from experimentally verified results. Importantly, the present sensor combination detects selected environmental conditions and does not independently measure overcurrent, earth fault, or line impedance. The prototype is consequently intended for supervised, isolated low-voltage educational demonstration and is not a substitute for certified power-system protection equipment.
KEYWORDS
This paper presented a hardware-based educational model for environmental hazard sensing and relay-controlled load isolation. A rain/moisture sensor and an IR flame sensor provide two independent inputs, while comparator-based circuitry generates switching signals for a two-channel relay arrangement. The relay contacts are intended to disconnect a low-voltage demonstration load when either selected environmental condition is detected. The design illustrates sensing, threshold comparison, relay actuation, and load isolation without requiring a programmable microcontroller. The supplied project documents support the design concept and expected qualitative behaviour but do not provide measured experimental results. Moreover, the two environmental sensors do not directly measure electrical fault current or voltage and therefore cannot independently establish short-circuit or other electrical fault conditions. The prototype should be treated only as a supervised low-voltage educational demonstrator. Additional electrical sensing, validation, and professional safety engineering would be necessary for any broader protection application.
[1] A. Yadav and Y. Dash, “An Overview of Transmission Line Protection by Artificial Neural Network: Fault Detection, Fault Classification, Fault Location, and Fault Direction Discrimination,” Advances in Artificial Neural Systems, vol. 2014, Article ID 230382, 2014. DOI: 10.1155/2014/230382. [2] O. A. Gashteroodkhani, M. Majidi, and M. Etezadi-Amoli, “Fire Hazard Mitigation in Distribution Systems through High Impedance Fault Detection,” Electric Power Systems Research, vol. 192, Article 106928, 2021. DOI: 10.1016/j.epsr.2020.106928. [3] M. Bindi, M. C. Piccirilli, A. Luchetta, and F. Grasso, “A Comprehensive Review of Fault Diagnosis and Prognosis Techniques in High Voltage and Medium Voltage Electrical Power Lines,” Energies, vol. 16, no. 21, Art. no. 7317, 2023. DOI: 10.3390/en16217317. [4] M. A. Chincholkar, A. S. Chormale, J. Shah, M.M. Udawant, R. Patil, and P. Deshpande, “Transmission Line Fault Detection using Flame Sensor,” in Proceedings of the 3rd International Conference on Automation, Computing and Renewable Systems (ICACRS), 2024, pp. 219–224.DOI: 10.1109/ICACRS62842.2024.10841735. [5] A. Aljohani and I. Habiballah, “High-Impedance Fault Diagnosis: A Review,” Energies, vol. 13, no. 23, Art. no. 6447, 2020. DOI: 10.3390/en13236447. [6] S. Khavari, R. Dashti, H. R. Shaker, and A. Santos, “High Impedance Fault Detection and Location in Combined Overhead Line and Underground Cable Distribution Networks Equipped with Data Loggers,” Energies, vol. 13, no. 9, Art. no. 2331, 2020. DOI: 10.3390/en13092331. [ 7] J. L. Blackburn and T. J. Domin, Protective Relaying: Principles and Applications, 4th ed. Boca Raton, FL, USA: CRC Press, 2014.
Publication Date
11/19/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
0
Total views since publication
PDF Downloads
0
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...