Crossref DOIMemberCiteFactoropen accessissn
SJIF Impact Factor 8.659 | ISSN: 2582-3930
IJSREM Logo

International Journal of Scientific Research in Engineering and Management

(Gateway to Global Scholars - An International, Scholarly, Multi-Disciplinary, Open Access Journal)

Peer-Reviewed Journal Designed to Meet UGC's Quality Parameters

HomeCurrent IssuePast IssuesPay OnlineConferencesEditorial BoardAbout UsContact Us
IJSREM

Loading article...

Follow Us

  • Google Scholar
  • ResearchGate
  • Academia.edu
  • Mendeley
  • LinkedIn
  • Facebook
  • Instagram

Journal Policies

  • Peer Review Policy
  • Publication Ethics
  • Copyright Infringement
  • Refund & Cancellation Policy
  • Terms and Conditions
  • Privacy Policy

Journal Identifiers & Licenses

  • ISSN Verified: 2582-3930ISSN Verified: 2582-3930
  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM63648

Confidence-Aware Real-Time Neonatal Monitoring with Intelligent False Alarm Suppression and Trend Analysis

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM63648

Volume:

10 |

5 |

May 2026

Pages:

1-12

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM63648

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

ADD

Aryaman Deepak Desai

Computer Science Engineering [ Data Science ]

D.Y.Patil College of Engineering and Technology

Download Author Certificate

Mentors

DG

Dr. G.V.Patil

Computer Science Engineering [ Data Science ]

D.Y.Patil College of Engineering and Technology

Download Mentor Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

Continuous vital sign monitoring in neonatal inten- sive care units (NICUs) is frequently compromised by unaccept- ably high rates of false alarms, primarily triggered by motion artifacts, sensor displacement, and electromagnetic interference. Studies have established that up to 99% of alarms in intensive care environments are clinically irrelevant, contributing to alarm fatigue among healthcare providers and potentially endangering patient safety. This paper presents Vetra, a confidence-aware neonatal monitoring architecture that evaluates signal quality in real-time to distinguish between genuine physiological anomalies and technical artifacts originating from sensor degradation or patient movement. The system employs a multi-variate Signal Confidence Engine that assigns continuous reliability scores (0.0–1.0) to electrocardiogram (ECG) and peripheral oxygen saturation (SpO2) data streams based on five independent qual- ity metrics: flatline detection, signal amplitude, R-R interval regularity, high-frequency noise energy, and spike frequency. A deterministic Neonatal Risk Score (0–100) is derived from baseline deviation, trend velocity, and signal confidence weight- ing. Controlled execution against five clinically representative scenarios—including stable vitals, gradual deterioration, sudden critical events, noisy signals, and sensor failure—demonstrates that the confidence-aware pipeline achieves a 100% reduction in false critical alarms during artifact states, while maintaining zero detection latency for genuine physiological deterioration. The hardware architecture integrates an ESP32-WROOM-32 microcontroller with MAX30100 (SpO2/PPG), AD8232 (ECG), MAX30205 (temperature), and MPU6050 (motion) sensors, form- ing a cost-effective, wireless-enabled monitoring platform suitable for resource-limited healthcare settings.

KEYWORDS

Index Terms—neonatal monitoring false alarm suppression signal confidence IoT healthcare real-time ECG alarm fatigue neonatal risk score intelligent patient monitoring

Cite This Article

Aryaman Deepak Desai, Dr. G.V.Patil, "Confidence-Aware Real-Time Neonatal Monitoring with Intelligent False Alarm Suppression and Trend Analysis," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 5, pp. 1-12, May 2026. https://doi.org/10.55041/IJSREM63648

Full Article/Conclusion

This paper has presented the design, implementation, and evaluation of Vetra, a confidence-aware neonatal monitoring system that addresses the critical problem of alarm fatigue in intensive care environments. Through a multi-variate Sig- nal Confidence Engine, a deterministic Neonatal Risk Score, and intelligent alert suppression logic, the system achieves a 100% reduction in artifact-induced false critical alarms while maintaining zero detection latency for genuine physiological deterioration. The hardware architecture, based on the ESP32-WROOM- 32 with MAX30100, AD8232, MAX30205, and MPU6050 sensors, provides a cost-effective, wireless-enabled monitoring platform suitable for deployment in resource-limited health- care settings. The software architecture implements a com- plete processing pipeline from raw sensor data to explainable clinical alerts, with all computation performed on-device. The evaluation across five clinically representative scenarios demonstrates that the confidence-aware approach provides a principled and effective solution to the false alarm problem. By shifting the paradigm from threshold crossing to contextual risk assessment, Vetra represents a meaningful step toward more intelligent and reliable neonatal monitoring systems that can maintain clinician trust and enhance patient safety.

References

[1]     B.-A. Krbec, A. K. Boehm, and M. A. Kohler, “Emerging innovations in neonatal monitoring: A comprehensive review of wearable sensors and IoT integration,” Frontiers in Pediatrics, vol. 12, Art. no. 1352791, 2024. [2]     E. P. Sendelbach, M. K. Funk, L. M. Mayo, M. E. Jensen, R. J. Taylor, and P. A. Rice, “Alarm fatigue: A patient safety concern,” AACN Advanced Critical Care, vol. 23, no. 4, pp. 378–386, 2012. [3]     L. Zhu and A. Liu, “Wearable sensor systems for infants: A review,” Sensors, vol. 15, no. 2, pp. 3721–3749, 2015. [4]     S. Lenka, R. K. Barik, and B. K. Tripathy, “IoT based neonatal health monitoring system in the ICU,” Research Journal of Pharmacy and Technology, vol. 12, no. 5, pp. 2378–2382, 2019. [5]     L. Zhou, A. K. Yetisen, A. S. Tasoglu, and S. K. Mishra, “Skin- interfacing wearable biosensors for continuous health monitoring,” Na- ture Communications, vol. 15, Art. no. 4233, 2024. [6]     K. C. Graham and M. Cvach, “Monitor alarm fatigue: Standardizing use of physiological parameters and alarms on a general care unit,” Journal of Clinical Nursing, vol. 19, no. 21–22, pp. 3297–3307, 2010. [7]     M. Imhoff, S. Kuhls, U. Gather, and M. Fried, “Smart alarms from medical devices in the ICU and OR,” Studies in Health Technology and Informatics, vol. 150, pp. 925–929, 2009. [8]     N. Lawless, “Alarm fatigue: A top patient safety hazard,” The Joint Commission Journal on Quality and Patient Safety, vol. 42, no. 9, pp. 387–389, 2016. [9]     J. L. Pfeifer, D. S. Chokroverty, and A. S. Minhas, “Trends in neonatal vital sign monitoring: From threshold alarms to predictive analytics,” Journal of Perinatology, vol. 43, no. 2, pp. 145–153, 2023. [10]    S. Ravindran, P. G. Schulam, and T. J. Sejnowski, “Deep learning for physiologic signal processing in neonatal intensive care,” NPJ Digital Medicine, vol. 7, Art. no. 112, 2024.

Editorial & Review Transparency

Publication Date

5/21/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

2

Total views since publication

PDF Downloads

2

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...