Computer Science Engineering [ Data Science ]
D.Y.Patil College of Engineering and Technology
Computer Science Engineering [ Data Science ]
D.Y.Patil College of Engineering and Technology
Continuous vital sign monitoring in neonatal inten- sive care units (NICUs) is frequently compromised by unaccept- ably high rates of false alarms, primarily triggered by motion artifacts, sensor displacement, and electromagnetic interference. Studies have established that up to 99% of alarms in intensive care environments are clinically irrelevant, contributing to alarm fatigue among healthcare providers and potentially endangering patient safety. This paper presents Vetra, a confidence-aware neonatal monitoring architecture that evaluates signal quality in real-time to distinguish between genuine physiological anomalies and technical artifacts originating from sensor degradation or patient movement. The system employs a multi-variate Signal Confidence Engine that assigns continuous reliability scores (0.0–1.0) to electrocardiogram (ECG) and peripheral oxygen saturation (SpO2) data streams based on five independent qual- ity metrics: flatline detection, signal amplitude, R-R interval regularity, high-frequency noise energy, and spike frequency. A deterministic Neonatal Risk Score (0–100) is derived from baseline deviation, trend velocity, and signal confidence weight- ing. Controlled execution against five clinically representative scenarios—including stable vitals, gradual deterioration, sudden critical events, noisy signals, and sensor failure—demonstrates that the confidence-aware pipeline achieves a 100% reduction in false critical alarms during artifact states, while maintaining zero detection latency for genuine physiological deterioration. The hardware architecture integrates an ESP32-WROOM-32 microcontroller with MAX30100 (SpO2/PPG), AD8232 (ECG), MAX30205 (temperature), and MPU6050 (motion) sensors, form- ing a cost-effective, wireless-enabled monitoring platform suitable for resource-limited healthcare settings.
KEYWORDS
This paper has presented the design, implementation, and evaluation of Vetra, a confidence-aware neonatal monitoring system that addresses the critical problem of alarm fatigue in intensive care environments. Through a multi-variate Sig- nal Confidence Engine, a deterministic Neonatal Risk Score, and intelligent alert suppression logic, the system achieves a 100% reduction in artifact-induced false critical alarms while maintaining zero detection latency for genuine physiological deterioration. The hardware architecture, based on the ESP32-WROOM- 32 with MAX30100, AD8232, MAX30205, and MPU6050 sensors, provides a cost-effective, wireless-enabled monitoring platform suitable for deployment in resource-limited health- care settings. The software architecture implements a com- plete processing pipeline from raw sensor data to explainable clinical alerts, with all computation performed on-device. The evaluation across five clinically representative scenarios demonstrates that the confidence-aware approach provides a principled and effective solution to the false alarm problem. By shifting the paradigm from threshold crossing to contextual risk assessment, Vetra represents a meaningful step toward more intelligent and reliable neonatal monitoring systems that can maintain clinician trust and enhance patient safety.
[1] B.-A. Krbec, A. K. Boehm, and M. A. Kohler, “Emerging innovations in neonatal monitoring: A comprehensive review of wearable sensors and IoT integration,” Frontiers in Pediatrics, vol. 12, Art. no. 1352791, 2024. [2] E. P. Sendelbach, M. K. Funk, L. M. Mayo, M. E. Jensen, R. J. Taylor, and P. A. Rice, “Alarm fatigue: A patient safety concern,” AACN Advanced Critical Care, vol. 23, no. 4, pp. 378–386, 2012. [3] L. Zhu and A. Liu, “Wearable sensor systems for infants: A review,” Sensors, vol. 15, no. 2, pp. 3721–3749, 2015. [4] S. Lenka, R. K. Barik, and B. K. Tripathy, “IoT based neonatal health monitoring system in the ICU,” Research Journal of Pharmacy and Technology, vol. 12, no. 5, pp. 2378–2382, 2019. [5] L. Zhou, A. K. Yetisen, A. S. Tasoglu, and S. K. Mishra, “Skin- interfacing wearable biosensors for continuous health monitoring,” Na- ture Communications, vol. 15, Art. no. 4233, 2024. [6] K. C. Graham and M. Cvach, “Monitor alarm fatigue: Standardizing use of physiological parameters and alarms on a general care unit,” Journal of Clinical Nursing, vol. 19, no. 21–22, pp. 3297–3307, 2010. [7] M. Imhoff, S. Kuhls, U. Gather, and M. Fried, “Smart alarms from medical devices in the ICU and OR,” Studies in Health Technology and Informatics, vol. 150, pp. 925–929, 2009. [8] N. Lawless, “Alarm fatigue: A top patient safety hazard,” The Joint Commission Journal on Quality and Patient Safety, vol. 42, no. 9, pp. 387–389, 2016. [9] J. L. Pfeifer, D. S. Chokroverty, and A. S. Minhas, “Trends in neonatal vital sign monitoring: From threshold alarms to predictive analytics,” Journal of Perinatology, vol. 43, no. 2, pp. 145–153, 2023. [10] S. Ravindran, P. G. Schulam, and T. J. Sejnowski, “Deep learning for physiologic signal processing in neonatal intensive care,” NPJ Digital Medicine, vol. 7, Art. no. 112, 2024.
Publication Date
5/21/2026
Peer Review Type
Double-Blind Peer Review
Review Rounds: 2
Documents
Article Views
2
Total views since publication
PDF Downloads
2
Total downloads since publication
Geographic Reach
5
Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.
Plagiarism Screening
This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.
Conflict of Interest
The authors declare no conflict of interest related to this research work.
Funding Information
No funding information available for this research.
Related research in the same subject area
Loading similar articles...