  • Crossref DOI: 10.55041Crossref DOI: 10.55041
  • SJIF Ranking: 08.659SJIF Ranking: 08.659
  • Licensed under CC BY 4.0Licensed under CC BY 4.0
  • ISO Certification: 9001:2015ISO Certification: 9001:2015
  • Indexed & Cited In: Google ScholarIndexed & Cited In: Google Scholar

Contact Us

International Journal of Scientific Research in Engineering and Management (IJSREM)

#62/1, New No 7, 1st Cross, 2nd Main, Ganganagar, R T Nagar, Bangalore North, Bangalore, Karnataka, India – 560032
[email protected]+91 93911 67991
logos
logos
Working Hours

Mon – Sat: 9:00 AM – 6:00 PM

Sunday: 10:00 AM – 4:00 PM

+91 93911 67991

© 2026 IJSREM – International Journal of Scientific Research in Engineering and Management. This is an open-access journal. Articles are published under the Creative Commons Attribution (CC BY 4.0) License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

DisclaimerPrivacy PolicyTerms and Conditions
ArticlePeer ReviewedOpen AccessPlagiarism Passed
Paper ID:IJSREM67093

Fire Safety Performance Of Facade Systems In High-Rise Buildings: An Analytical Investigation

Stream/Area:

-

Subject:

-

Paper ID:

IJSREM67093

Volume:

10 |

9 |

Sep 2026

Pages:

1-12

Publication Frequency:

Monthly (12 issues per year)

DOI
Digital Object Identifier
10.55041/IJSREM67093

License:International Journal of Scientific Research in Engineering and Management follows the Creative Commons Attribution 4.0 (CC BY 4.0) License, allowing free use and distribution with proper attribution.

Share this article:

Authors

KC

Kamlesh Chore

FIRE TECHNOLOGY & SAFETY ENGINEERING

VIKRANT UNIVERSITY, GWALIOR

Download Author Certificate
DSKY

Dr. Sandeep Kumar Yadav

FIRE TECHNOLOGY & SAFETY ENGINEERING

VIKRANT UNIVERSITY, GWALIOR

Download Co-Author Certificate

Author Services & Downloads

Full ArticlesAcceptance Certificate

Abstract

The rapid growth of high-rise buildings has increased dependence on lightweight façade systems, rainscreen assemblies, aluminium composite panels, insulation materials, glazing systems, and other advanced envelope technologies. Although façade systems provide architectural, thermal, acoustic, and environmental benefits, the incorporation of combustible materials can significantly increase the potential for rapid external fire spread. The configuration of the façade, including combustible cladding, insulation, air cavities, joints, openings, cavity barriers, and fixing systems, can create conditions for vertical and horizontal flame propagation. The chimney effect generated within ventilated façade cavities may further accelerate fire development and threaten multiple floors within a short period. This research presents a systematic review of façade fire safety in high-rise buildings, with particular emphasis on material combustibility, façade configuration, insulation, cavity geometry, fire barriers, external fire exposure, and smoke production. The study examines relevant research findings and fire-safety principles associated with combustible aluminium composite panels, polymeric insulation, rainscreen façades, and non-combustible cladding systems. The study also considers the regulatory context of the National Building Code of India (NBC 2016), together with international approaches including NFPA and BS 8414-based façade assessment. Previous experimental research indicates that the chimney effect can substantially increase burning rate, flame height, and temperature within façade cavities, while numerical investigations demonstrate that cavity width, cavity barriers, panel joints, and material combustibility strongly influence fire propagation. Based on the reviewed literature, a risk-based façade fire safety framework is proposed consisting of material selection, system-level fire testing, cavity-barrier design, compartmentation, ignition prevention, inspection and maintenance, fire-service access, and computational fire modelling. The study concludes that façade fire safety cannot be evaluated solely from the combustibility classification of an individual material; the complete façade assembly and its interaction with fire exposure, geometry, ventilation, and building systems must be assessed. The proposed framework can support safer façade design and improve fire-risk management in high-rise buildings, particularly in the Indian context.

KEYWORDS

High-rise buildings façade fire safety combustible cladding aluminium composite panels insulation cavity barrier chimney effect fire spread NBC 2016 CFD FDS.

Cite This Article

Kamlesh Chore, Dr. Sandeep Kumar Yadav, "Fire Safety Performance Of Facade Systems In High-Rise Buildings: An Analytical Investigation," International Journal of Scientific Research in Engineering and Management, vol. 10, no. 9, pp. 1-12, Sep 2026. https://doi.org/10.55041/IJSREM67093

Full Article/Conclusion

The fire safety of façades is a critical component of high-rise building safety. Modern façade systems provide important architectural and environmental benefits, but the incorporation of combustible cladding, polymeric insulation and ventilated cavities can create pathways for rapid external fire spread. The reviewed literature indicates that façade fire behaviour results from the interaction between material properties, cavity geometry, ventilation, fire exposure, wind, façade openings, joints and fire barriers. Experimental studies have demonstrated that chimney effects can significantly increase burning characteristics, while numerical investigations have highlighted the influence of cavity dimensions, barrier arrangements and material combustibility. The central conclusion of this research is that façade fire safety should be assessed at the system level rather than solely at the individual-material level. A façade may contain a non-combustible external surface while still incorporating combustible insulation, membranes or adhesives. Conversely, a carefully engineered system can incorporate materials with limited combustible content while maintaining acceptable fire performance when designed, tested and installed appropriately. For Indian high-rise construction, NBC 2016 provides an essential regulatory framework, but effective fire safety also requires detailed engineering evaluation, appropriate material selection, system-level testing, effective cavity barriers, active fire protection and continuous inspection. Future research should combine experimental façade fire testing, FDS/CFD modelling, machine-learning-based risk prediction and field inspection data to develop a quantitative façade fire-risk model specifically applicable to Indian climatic, construction and regulatory conditions.

References

1.                Bureau of Indian Standards. National Building Code of India 2016 (NBC 2016), Part 4: Fire and Life Safety. BIS, New Delhi. 2.                McKenna, S. T., Jones, N., Peck, G., Dickens, K., Pawelec, W., Oradei, S., Harris, S., Stec, A. A., & Hull, T. R. (2019). Fire behaviour of modern façade materials – Understanding the Grenfell Tower fire. Journal of Hazardous Materials, 368, 115–123. 3.                Hassan, M. K., Hossain, M. D., Gilvonio, M., Rahnamayiezekavat, P., Douglas, G., Pathirana, S., & Saha, S. (2022). Numerical investigations on the influencing factors of rapid fire spread of flammable cladding in a high-rise building. Fire, 5(5), 149. 4.                Hassan, M. K., et al. (2021). Experimental investigations on the influence of chimney-effect on fire response of rainscreen façades in high-rise buildings. Journal of Building Engineering, 44, 103257. 5.                Hasnat, M. R., Hassan, M. K., & Saha, S. (2026). Fire behaviour and thermal characterisation of different types of non-combustible cladding panels used in high-rise buildings. Fire Technology, 62, Article 31. 6.                NFPA Research Foundation. High Rise Buildings with Combustible Exterior Façade Systems: Fire Risk Assessment Tool – Background and Development of the Tool. 7.                NFPA Research Foundation. Fire Safety Challenges of Green Buildings and Attributes. 8.                Choudhary, S., Kurmi, D., Choure, K. K., & Yadav, S. K. An Analytical Study of Fire Spread Mechanisms in High-Rise Buildings Considering Facade Materials. 9.                Renganathan, R., & Judson, L. Facade System and Material Selection Choices to Prevent Fire Spreading in the Commercial Building. 10.             A Critical Appraisal of the UK’s Regulatory Regime for Combustible Façades. Fire Technology.    

Editorial & Review Transparency

Publication Date

9/3/2026

Peer Review Type

Double-Blind Peer Review

Review Rounds: 2

Documents

Review Report (Confidential)
Copyright Form (Office)

Article Metrics & Impact

Article Views

1

Total views since publication

PDF Downloads

8

Total downloads since publication

Geographic Reach

5

Indexing, Archiving & Preservation

Google Scholar
Academia
ResearchGate
Crossref
SSRN
Semantic Scholar
Thomson Reuters
WorldCat
Mendeley
OpenAlex
EBSCO
Zenodo

Digital Preservation: This article is permanently archived on Zenodo and complies with all data preservation standards across major indexing platforms.

Ethics, Compliance & Transparency

Plagiarism Screening

This manuscript has been checked for plagiarism using TurnitinPlagiarismChecker software.

Conflict of Interest

The authors declare no conflict of interest related to this research work.

Funding Information

No funding information available for this research.

Similar & Recommended Articles

Similar Articles by Topic

Related research in the same subject area

Loading similar articles...